| 2013-07-25 16:37:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC 2010 ACCESSIBILITY: | | | | | | 1. SEE 106.1, DEFINITIONS, "ELEVATED PLAY COMPONENT" | | | AND "GROUND LEVEL PLAY COMPONENT". THE MANUFACTURER | | | PROVIDED DATA SHEETS WHICH STATE THAT ALL COMPONENTS | | | ARE "GROUND LEVEL" AND NONE ARE ELEVATED. PLEASE SEE | | | DEFINITIONS AND PROVIDE FURTHER EXPLANATION AS THE | | | EQUIPMENT PROPOSED APPEARS TO BE AN ELEVATED PLAY | | | COMPONENT. SEE ALSO SECTION 240. | | | | | | 2. PROVIDE DETAILS ON ACCESSIBLE ROUTE 1008.2.6 | | | INCLUDING DIMENSIONS AND SPECIFICATIONS. PROVIDE SPEC | | | SHEETS TO SHOW THAT IT COMPLIES WITH ASTM F 1951. | | | | | | 3. PROVIDE DETAILS ON THE USE ZONES, 1008.2.6.2. | | | PROVIDE SPEC SHEETS TO SHOW THAT PROPOSED GROUND | | | SURFACES COMPLY WITH ASTM F 1292. | | | | | | 4. SEE 240.2.2, AT LEAST 50% OF ELEVATED PLAY | | | COMPONENTS ARE TO BE ON AN ACCESSIBLE ROUTE AND SHALL | | | COMPLY WITH 1008.4. REVISE PLAN TO SHOW COMPLIANCE. | | | | | | 5. THE LINK PROVIDED PREVIOUSLY HAS CHANGED. SEE THE | | | FOLLOWING SITE FOR FURTHER GUIDANCE: | | | | | | HTTP://WWW.ACCESS-BOARD.GOV/GUIDELINES-AND-STANDARDS/RE | | | CREATION-FACILITIES/GUIDES/PLAY-AREAS |
|