| Date |
Text |
| 2013-07-03 10:49:32 | BUILDING PLAN REVIEW |
| | PERMIT: 13050887 |
| | ADD: 3620 S DIXIE HWY |
| | CONT: L & H HOMEBUILDERS INC |
| | TEL: (561)436-0688 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | COMPLIED 7/11/13/ JW. NOTE: SHEET SP-1 |
| | I SPOKE WITH GARY CLEMENT THIS MORNING (7:00 AM) ABOUT |
| | REQUIRED PERMITS AND OR DEFIENCIES IN PLANS: |
| | A) A NEW SITE PLAN SP-1 WILL BE SUBMITTED INDICATING A |
| | BIKE RACK FOR COMMERCIAL UNITS AND MAIL KIOSK FOR |
| | COMMERCIAL UNITS. |
| | B) A SEPERATE PERMIT WILL BE REQUIRED FOR POOL PAVER |
| | DECK. |
| | C) A SEPERATE SECURITY FENCE WILL BE REQUIRED FOR THE |
| | POOL, GATE WILL NEED TO COMPLY WITH 2010 FBC-B |
| | 424.1.3.1.9 LATCH AT 54 INCHES. |
| | |
| | POOL CABANA |
| | 1ST REVIEW |
| | DATE: JULY 03/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) SHEET SP-4 CANVAS AWNING BY OTHERS, SHOP DRAWINGS TO |
| | FOLLOW, THERE IS NO DESIGN CRITERIA FOR THE CANVAS |
| | AWNING: |
| | 1A) 2010 FBC-B 3105.3.1 FLAME SPREAD OF 25 OR LESS, |
| | TESTING IN ACCORDANCE WITH ASTM E-84 |
| | 1B) MISSING WIND DESIGN CRITERIA 2010 FBC-B 3105.4 |
| | 1C) SP-4 NOR S-3 PROVIDES FOUNDATION PADS FOR AWNING |
| | COLUMNS, WILL HAVE PAVER DECK. |
| | |
| | 2) SHEET SP-4 POOL CABANA RESTROOM DOOR WILL NEED TO |
| | COMPLY WITH THE 2010 FBC ACCESSIBILITY CODE |
| | 404.2.4.1(I) SIDE APPROACH 54 INCH WIDTH REQUIREMENT. |
| | |
| | 3) SHEET SP-4 DRINKING FOUNTAIN WILL NEED TO SHOW |
| | HEIGHT REQUIRIMENTS 2010 FBC ACCESSIBILITY CODE 602.4 & |
| | 602.7, THEY ARE NOT INCLUDED IN ACCESSIBLE ELEMENTS |
| | FOUND ON SP-5. |
| | |
| | 4) SHEET SP-5 WATER CLOSET DETAILS ARE NOT CLEAR AS TO |
| | REQUIRED LOCATION FROM WALL, IT APPEARS TO SAY 18 INCH |
| | MINIMUM. 2010 FBC-ACCESSIBLITY CODE 604.2 LOCATION 16 |
| | INCHES TO 18 INCHES. |
| | |
| | 5) SHEET S-1 WALL & SIGN DETAILS INDICATE UNDER THE |
| | HEADING DESIGN PARAMETERS OCCUPANCY CLASSIFICATION R3 |
| | PLEASE CORRECT TO UTILITY, 2010 FBC-B 312.1. |
| | |
| | 6) SHEET S-2 DUMPSTER ENCLOSURE & KIOSK DETAILS |
| | INDICATE UNDER THE HEADING DESIGN PARAMETERS OCCUPANCY |
| | CLASSIFICATION R3 PLEASE CORRECT TO UTILITY, 2010 FBC-B |
| | 312.1. |
| | |
| | 7) SHEET S-3 POOL CABANA DETAILS INDICATE UNDER THE |
| | HEADING DESIGN PARAMETERS OCCUPANCY CLASSIFICATION R3 |
| | PLEASE CORRECT TO A-5 2010 FBC-B 303.1. |
| | |
| | 8) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 9) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.41 COMPONENTS & CLADDING |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | 10) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |