2013-06-03 12:32:37****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FOR THE SHUTTERS, COMPLETE THE SAMPLE INSTALLATION
 SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE
 COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301,
 FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN
 THE LOBBY OR ON THE INTERNET AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
 2. PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS WILL
 BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 1 ABOVE. FBC R301, FBC1609,
 FBC*106.
  
 3. SEE FBC 1003.6, MEANS OF EGRESS CONTINUITY: THE PATH
 OF EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE
 INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS
 OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER.
 OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH
 OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY
 THIS CHAPTER.
  
 SHUTTERS WHICH BLOCK THE EXIT/MEANS OF EGRESS ARE
 PERMITTED ON A CASE BY CASE BASIS. ON THE SHUTTER
 FLOOR/LOCATION PLAN, INCLUDE THE EXITING PLAN TO BE
 IMPLEMENTED WHEN SHUTTERS ARE IN TEH CLOSED POSITION.
  
 4. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED.
 PLEASE CALL 561-233-5025 FOR MORE INFORMATION.
  
 5. THIS PARCEL IS LOCATED IN THE SPECIAL HAZARD FLOOR
 ZONE A7, BFE 12' (MAP 120229 0020 B). PROVIDE AN
 ELEVATION CERTIFICATE "CONSTRUCTION DRAWINGS." TWO
 ADDITIONAL ELEVATION CERTIFICATES WILL BE REQUIRED -
 "UNDER CONSTRUCTION" AND "FINAL." FBC 107.2.5, 1612.5.
  
 CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546(B)
 REQUIRES THAT THE FFE AND ALL MECHANICAL EQUIPMENT BE
 6" ABOVE BFE. PLEASE CONTACT ME IF YOU NEED ASSISTANCE
 WITH UNDERSTANDING HOW TO COMPLY WITH THIS REQUIREMENT.
  
 6. S001 PROPOSES WIND SPEED VULT AS 150MPH, RISK
 CATEGORY II. THE CITY OF WEST PALM BEACH LIES BETWEEN
 THE 160MPH AND 170MPH LINES. BASED ON LAT/LONG, THIS
 PARCEL IS LOCATED IN THE 168MPH WIND ZONE FOR RISK
 CATEGORY II. WWW.ATCOUNCIL.ORG (WIND SPEED) FBC 1609.1.
 PLEASE REVISE DESIGN CRITERIA AND OTHER ITEMS AS
 APPLICABLE.
 7. THIS PARCEL APPEARS TO BE LOCATED IN EXPOSURE C, SEE
 FBC 1609.4.3.
  
 8. SEE SECTION 3.3 OF THE SOILS REPORT, AND FOOTING
 DETAILS ON S500, A310. 18" EMBEDMENT RECOMMENDED, 16"
 PROPOSED. 16" COMPLIES WITH FBC 1809.4 BUT PLEASE HAVE
 EOR ACKNOWLEDGE RECEIPT OF SOILS REPORT AND
 RECOMMENDATIONS OR REVISE DETAILS. IF REVISED, PLEASE
 CHECK ALL SHEETS AS OTHER PAGES MAY BE AFFECTED.
  
 9. DETAIL 4-S500, FOOTING DEPTH NOT CLEAR (TOSL = 0'0",
 TO FOOTING = 0'0"), PLEASE REVISE, FBC 107.
  
 10. PLEASE REVISE SHEET A100 TO SHOW DISTANCE BETWEEN
 EXISTING TIGER NIGHT HOUSE AND PROPOSED TIGER NIGHT
 HOUSE AND LOCATION OF ASSUMED PROPERTY LINE, FBC 602,
 FBC TABLE 705.8.
  
 11. A101, PROVIDE PRODUCT APPROVAL FOR THE HM DOOR
 (KEYNOTE LEGEND #5), FAC 9N-3, FBC 1609.
  
 12. THE CROSSOVER DETAIL ON SHEET A501 WILL REQUIRE A
 SEPARATE PERMIT. HOWEVER, PLEASE NOTE THE FOLLOWING:
 GUARDS, OPENING & HEIGHT TO COMPLY WITH FBC 1013.3 AND
 1013.2; HANDRAIL EXTIONS TO COMPLY WITH FBC 1012.6;
 HANDRAIL HEIGHT TO COMPLY WITH FBC 1012.2.
  
 13. THE OPTIONS SHOWN ON THE ARCHITECTURAL SHEETS WILL
 REQUIRE A REVISION WITH STRUCTURAL DETAILS AND PRODUCT
 APPROVAL (ROOF) IF ELECTED TO BE A PART OF THIS PERMIT.
 SIGNS, GATES, FENCES, AND OTHER FREE STANDING ELEMENTS
 REQUIRE SEPARATE PERMITS (ADVISORY ONLY).
  
  