| Plan Review Notes For Permit 13050041 |
| Permit Number |
13050041 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-05-02 15:59:10 | 1. PROVIDE PANEL SCHEDULE SHOWING EXISTING AND NEW | | | CIRCUITS | | | 2. ALL OUTLETS TO BE AFCI PROTECTED PER NEC 210.12B | | | 3. ALL RECEPTACLES TO BE TAMPER RESISTANT PER NEC | | | 406.11 | | | 4. ELECTRICAL PERMIT RFEQUIRED |
|