Plan Review Notes
Plan Review Notes For Permit 13041076
Permit Number 13041076
Review Stop B
Sequence Number 1
Notes
Date Text
2013-05-31 12:34:13BUILDING PLAN REVIEW
 PERMIT: 13041076
 ADD:9861 OKEECHOBEE BLVD
 CONT: SECURITY VAULT WORKS
 TEL: (704)399-4166 EXT 1503
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 5/31/2013
 ACTION: DENIED
  
 1) PLEASE SHOW COMPLIANCE WITH:
 2010 FBC-ACCESSIBILITY CODE;
 1A) 707.3 OPERABLE PARTS. OPERABLE PARTS SHALL COMPLY
 WITH 309. UNLESS A CLEAR OR CORRECT KEY IS PROVIDED,
 EACH OPERABLE PART SHALL BE ABLE TO BE DIFFERENTIATED
 BY SOUND OR TOUCH, WITHOUT ACTIVATION.
  
 1B) 707.5 SPEECH OUTPUT. MACHINES SHALL BE SPEECH
 ENABLED. OPERATING INSTRUCTIONS AND ORIENTATION,
 VISIBLE TRANSACTION PROMPTS, USER INPUT VERIFICATION,
 ERROR MESSAGES, AND ALL DISPLAYED INFORMATION FOR FULL
 USE SHALL BE ACCESSIBLE TO AND INDEPENDENTLY USABLE BY
 INDIVIDUALS WITH VISION IMPAIRMENTS. SPEECH SHALL BE
 DELIVERED THROUGH A MECHANISM THAT IS READILY AVAILABLE
 TO ALL USERS, INCLUDING BUT NOT LIMITED TO, AN INDUSTRY
 STANDARD CONNECTOR OR A TELEPHONE HANDSET. SPEECH SHALL
 BE RECORDED OR DIGITIZED HUMAN, OR SYNTHESIZED.
  
 1C) 707.6.1 INPUT CONTROLS. AT LEAST ONE TACTILELY
 DISCERNIBLE INPUT CONTROL SHALL BE PROVIDED FOR EACH
 FUNCTION. WHERE PROVIDED, KEY SURFACES NOT ON ACTIVE
 AREAS OF DISPLAY SCREENS, SHALL BE RAISED ABOVE
 SURROUNDING SURFACES. WHERE MEMBRANE KEYS ARE THE ONLY
 METHOD OF INPUT, EACH SHALL BE TACTILELY DISCERNABLE
 FROM SURROUNDING SURFACES AND ADJACENT KEYS.
  
 1D) 707.6.2 NUMERIC KEYS. NUMERIC KEYS SHALL BE
 ARRANGED IN A 12-KEY ASCENDING OR DESCENDING TELEPHONE
 KEYPAD LAYOUT. THE NUMBER FIVE KEY SHALL BE TACTILELY
 DISTINCT FROM THE OTHER KEYS.
  
 1E)707.6.3 FUNCTION KEYS. FUNCTION KEYS SHALL COMPLY
 WITH 707.6.3.
  
 1F) 707.6.3.1 CONTRAST. FUNCTION KEYS SHALL CONTRAST
 VISUALLY FROM BACKGROUND SURFACES. CHARACTERS AND
 SYMBOLS ON KEY SURFACES SHALL CONTRAST VISUALLY FROM
 KEY SURFACES. VISUAL CONTRAST SHALL BE EITHER
 LIGHT-ON-DARK OR DARK-ON-LIGHT.
 EXCEPTION: TACTILE SYMBOLS REQUIRED BY 707.6.3.2 SHALL
 NOT BE REQUIRED TO COMPLY WITH 707.6.3.1.
  
 1G) 707.6.3.2 TACTILE SYMBOLS. FUNCTION KEY SURFACES
 SHALL HAVE TACTILE SYMBOLS AS FOLLOWS: ENTER OR PROCEED
 KEY: RAISED CIRCLE; CLEAR OR CORRECT KEY: RAISED LEFT
 ARROW; CANCEL KEY: RAISED LETTER EX; ADD VALUE KEY:
 RAISED PLUS SIGN; DECREASE VALUE KEY: RAISED MINUS
 SIGN.
  
 1H)707.7 DISPLAY SCREEN. THE DISPLAY SCREEN SHALL
 COMPLY WITH 707.7.
  
 1I)707.7.1 VISIBILITY. THE DISPLAY SCREEN SHALL BE
 VISIBLE FROM A POINT LOCATED 40 INCHES (1015 MM) ABOVE
 THE CENTER OF THE CLEAR FLOOR SPACE IN FRONT OF THE
 MACHINE.
  
 1J) 707.7.2 CHARACTERS. CHARACTERS DISPLAYED ON THE
 SCREEN SHALL BE IN A SANS SERIF FONT. CHARACTERS SHALL
 BE 3/16 INCH (4.8 MM) HIGH MINIMUM BASED ON THE
 UPPERCASE LETTER ?I?. CHARACTERS SHALL CONTRAST WITH
 THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK
 BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
  
 1K)707.8 BRAILLE INSTRUCTIONS. BRAILLE INSTRUCTIONS FOR
 INITIATING THE SPEECH MODE SHALL BE PROVIDED. BRAILLE
 SHALL COMPLY WITH 703.3.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved