| Plan Review Notes For Permit 13040935 |
| Permit Number |
13040935 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-06-12 09:05:38 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) PROVIDE A SITE PLAN OR SURVEY THAT SPECIFIES THE | | | DISTANCE TO THE PROPERTY LINE ON THE SIDE OF THE GARAGE | | | WHERE THE PROPOSED WINDOW IS LOCATED. SEE FBCR302.1 AND | | | TABLE R302.1 FOR REQUIRED FIRE SEPARATION DISTANCE FOR | | | OPENINGS. | | | | | | 2) THE OCCUPANCY, TYPE OF CONSTRUCTION AND LEVEL OF | | | ALTERATION ON SHEET A-1 ARE INCORRECT. THIS IS A SINGLE | | | FAMILY RESIDENCE WHICH IS AN R-3 OCCUPANCY (FBC SECTION | | | 310.1), THE TYPE OF CONSTRUCTION IS VB (FBC SECTION | | | 602) AND IT IS A LEVEL 2 ALTERATION PER FBC EXISTING | | | BUILDING SECTION 404. PLEASE CORRECT. | | | | | | 3) SPECIFY THE WINDSPEED AND EXPOSURE CATEGORY FOR THIS | | | PROJECT ON THE PLANS. THE WINDSPEED IS 170 MPH VULT / | | | 132 VASD AND THE EXPOSURE CATEGORY IS C. FBC R301.2.1.1 | | | AND R301.2.1.4.3 | | | | | | 4) SHOW COMPLIANCE WITH FBC ENERGY SECTION 402 BY | | | SUBMITTING THE REQUIRED ENERGY COMPLIANCE FORMS FOR THE | | | PROPOSED HABITABLE SPACE. | | | | | | 5) SHOW COMPLIANCE WITH FBC R314 .3.1 FOR REQUIRED | | | SMOKE ALARMS. | | | | | | 6) THE TITLE BLOCK ON THE PLAN SHEETS ARE MISSING SOME | | | OF THE MINIMUM INFORMATION REQUIRED BY FAC 61G1-16.004. | | | PLEASE INCLUDE THE LICENSE NUMBER OF THE ARCHITECTURAL | | | FIRM AND THE PRINTED NAME OF THE PERSON SEALING THE | | | PLANS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|