Plan Review Notes
Plan Review Notes For Permit 13040663
Permit Number 13040663
Review Stop B
Sequence Number 1
Notes
Date Text
2013-04-22 12:39:48BUILDING REVISION CHECKLIST.
  
 1- GARAGE DOOR PRODUCT APPROVAL FL5684-R5 SUBMITTED
 DOESN'T MEET THE DESIGN PRESSURES THAT WERE CALCULATED
 BY THE ARCHITECT. NEED TO PROVIDE PRODUCT APPROVAL THAT
 MEETS THE CALCULATED DESIGN PRESSURES. SEC. 107.2.1
 CITY AMENDMENTS TO FBC.
  
 2- ARCHITECT OF RECORD NEED TO REVIEW AN APPROVE IN
 WRITING (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS
 AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 3- NEED TO PROVIDE ALL THE INFORMATION THAT WAS
 REQUESTED ON PROVISO DATED 7/27/10 TO AVOID ANY DELAYS
 OR CONFLICTS ON FINAL INSPECTION. INFORMATION WAS NEVER
 SUBMITTED FOR REVIEW. SEE COPY OF PROVISO BELOW:
  
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 -1- PROVIDE PRODUCT APPROVALS FOR: (A) GARAGE DOOR THAT
 MEETS THE DESIGN PRESSURES CALCULATED ON SHEET A-2.0.
 (B) EXTERIOR INSWING AND OUTSWING DOORS. (C) WINDOW
 MULLIONS. (D)STRUCTURAL CONNECTORS. (E) CURRENT ROOF
 TILE AND POLYFOAM ADHESIVE. NOA 07-1023.11 WAS CLOSED
 BY MIAMI-DADE. (F) FLAT ROOF. PROVIDE SIGNED AND SEALED
 RAS 117 CALCULATIONS.
 -2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS.
 -3- ARCHITECT TO COORDINATE WINDOW MATERIAL SPECIFIED
 ON PLANS AND PRODUCT APPROVAL SUBMITTED TO MATCH.
 -4- ENERGY CALCULATIONS: (A) PROVIDE COMPLETE
 INFORMATION ON TOP OF FORM. (B) ENGINEER TO PROVIDE ALL
 HIS INFORMATION AS REQUIRED BY CHAPTER 471 FLORIDA
 STATUTES. (C) REVISE TYPE OF ROOF SHOWN ON PAGE 2 OF
 ENERGY CALCULATIONS TO MATCH PLANS. (D) COORDINATE
 WINDOW MATERIAL WITH REVISED WINDOW MATERIAL REQUESTED
 ON ITEM #3 ABOVE.
 -5- OUTDOOR FIREPLACE: (A) PROVIDE COMPLETE FRAMING
 DETAILS FOR FIREPLACE AND CHIMNEY. SPECIFY ALL FRAMING
 MEMBERS AND CONNECTORS TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301. (B) DESIGNER OF RECORD
 TO REVIEW AND APPROVE IN WRITING OUTDOOR FIREPLACE
 COMPLETE PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE.
 -6- GUARDRAILS AND HANDRAILS: (A) MISSING GUARDRAILS
 AND HANDRAILS ON WEST STAIRS. SEE SHEET A-1. (B) REVISE
 DETAIL #12 ON SHEET A-1.1. REVISE PICKET SPACING. A 4"
 SPHERE SHALL NOT PASS TRU. SEC. R312.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712