Plan Review Notes
Plan Review Notes For Permit 13040634
Permit Number 13040634
Review Stop B
Sequence Number 1
Notes
Date Text
2013-04-25 11:48:39BUILDING PLAN REVIEW
 PERMIT: 13040634
 ADD: 5707 S DIXIE HWY SUITE D
 CONT: ACECA CONSTRUCTION
 TEL: (561)574-7733
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 4/25/2013
 ACTION: DENIED
  
 1) PLEASE REVIEW NEW BREAK ROOM DOOR SWING AND ACHIEVE
 CODE COMPLIANCE WITH 2010 FBC-B 1008.1.9.11
 DURING ITS SWING, ANY DOOR IN A MEANS OF EGRESS SHALL
 LEAVE UNOBSTRUCTED AT LEAST ONE HALF OF THE REQUIRED
 WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY, OR LANDING,
 NOR PROJECT MORE THAN 7 INCHES (178 MM) INTO THE
 REQUIRED WIDTH OF AN AISLE, CORRIDOR, PASSAGEWAY OR
 LANDING, WHEN FULLY OPEN.
  
 2) THE DOOR BETWEEN THE WAITING ROOM AND CORRIDOR DOES
 NOT APPEAR TO HAVE 18 INCHES LATCH SIDE OF THE DOOR.
 PLEASE SEE 2010 FL ACCESSIBILITY CODE SECTION 404.2.4.1
 & TABLE 404.2.4.1.
  
 3) THE RECEPTION AREA COUNTER TOP WILL ALSO NEED TO
 MEET THE 2010 FLACCESSIBILTY CODE 904.3.3 CHECK WRITING
 SURFACES.
 WHERE PROVIDED, CHECK WRITING SURFACES SHALL COMPLY
 WITH 902.3.
 2010 FL ACCESSIBILITY CODE 902.3 HEIGHT. THE TOPS OF
 SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34
 INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]