| Plan Review Notes For Permit 13040580 |
| Permit Number |
13040580 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-04-16 11:41:36 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | THE DOCUMENTS PROVIDED DO NOT INCLUDE A PRODUCT NAME. | | | SHOW COMPLIANCE FOR THE FOLLOWING REQUIREMENTS FOR THE | | | PROPOSED UNDERLAYMENT: | | | | | | 1. FBC 1207.2 AND 1207.3, THE TEST DATA SUBMITTED IS | | | MISSING PAGE 1. | | | | | | 2. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | SEE 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM | | | E 84 OR UL 723. | | | | | | |
|