2013-06-03 14:44:57BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- TRUSS PACKAGE:
 A) TRUSS ENGINEER TO PROVIDE ORIGINAL SIGNATURE (NOT
 COPY) IN ALL DRAWINGS WITH HIS SIGNATURE.
  
 B) TRUSS PACKAGE SUBMITTED DOESN'T COMPLY WITH SEC.
 61G15-31.003, EACH DRAWING SHALL HAVE A TITLE BLOCK
 WITH ENGINEER'S NAME, LICENSE, ADDRESS AND DATE OF THE
 DRAWING. AND, THE PAGES NEED TO BE NUMBERED TO MATCH
 INDEX SHEET.
  
 2- SHEET S-2:
 A) ENGINEER OF RECORD TO REVISE ALL THE CONNECTORS THAT
 DON'T MEET THE UPLIFT CALCULATIONS AS SHOWN ON THE
 TRUSS PACKAGE.