| 2013-04-29 16:33:12 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| | COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- VALUATION SPECIFIED IN THE PERMIT APPLICATION IS TOO |
| | LOW. SEC. 109.3 CITY AMENDMENTS TO FBC. VALUATION |
| | INCLUDES ALL THE LABOR, MATERIALS, OVERHEAD AND PROFIT |
| | AND DESIGN PROFESSIONALS FEES. VALUATION WAS UPDATED. |
| | PERMIT FEE BALANCE IS $4350.39. |
| | |
| | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) 1 HOUR FIRE RATED GLASS BLOCK ASSEMBLY AS REQUIRED |
| | ON THE ZERO LOT LINE WALL. |
| | |
| | B) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| | |
| | C) SIMPSON MBHU GIRDER TRUSS HANGER AS SPECIFIED ON |
| | PLANS. |
| | |
| | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | ABOVE PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 |
| | CITY AMENDMENTS TO FBC. |
| | |
| | 4- PROVIDE SOIL TEST REPORT. SEC. R401.4 OF 2010 |
| | FBC-RESIDENTIAL. |
| | |
| | 5- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING |
| | METHOD AND WIND UPLIFT AS REQUIRED BY SEC. 107.2.1.2 |
| | CITY AMENDMENTS TO VERIFY COMPLIANCE WITH THE PRODUCT |
| | APPROVAL SUBMITTED. |
| | ***NOTE: COMPONENTS AND CLADDING UPLIFT PRESSURES |
| | SPECIFIED ON THE PLANS COVER SHEET ARE INCORRECT. THEY |
| | DON'T CORRESPOND TO EXPOSURE "C" AS REQUIRED BY SEC. |
| | R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. AND, CLARIFY WHY |
| | ROOF ZONE 2 AND 3 HAVE THE SAME UPLIFT PRESSURES. |
| | REVISE AS REQUIRED. |
| | |
| | 6- PROVIDE DETAILS/SPECIFICATIONS SHOWING COMPLIANCE |
| | WITH THE FOOTING MINIMUM DEPTH AS REQUIRED BY SEC. |
| | R403.1.4 OF 2010 FBC- RESIDENTIAL AND THE CLEARANCE |
| | BETWEEN EXTERIOR WALL COVERING AND FINAL EARTH GRADE AS |
| | REQUIRED BY SEC. R704 OF 2010 FBC-RESIDENTIAL. |
| | |
| | 7- PROVIDE MANUFACTURER SPECS FOR BBQ GRILL THAT IS |
| | DESIGNED AND LISTED TO BE INSTALLED IN A PORCH AS SHOWN |
| | ON PLANS. SEC. M1901.2 OF 2010-FBC-RESIDENTIAL. |
| | |
| | 8- SURVEY SAYS PROPOSED 2 STORY RESIDENCE. PLANS SHOW |
| | ONE STORY. REVISE AS REQUIRED. SEC. 107.2.1 CITY |
| | AMENDMENTS TO FBC. |
| | |
| | 9- TRUSS PACKAGE: |
| | A) TRUSS ENGINEER TO PROVIDE ORIGINAL SIGNATURE (NOT |
| | COPY) AS REQUIRED BY CHAPTER 471 FLORIDA STATUTES. |
| | |
| | B) TRUSS PACKAGE SUBMITTED DOESN'T COMPLY WITH SEC. |
| | 61G15-31.003, IF ENGINEER WANTS TO USE A COVER SHEET |
| | INSTEAD OF SIGNING AND SEALING EACH INDIVIDUAL TRUSS |
| | SHEET. ENGINEER TO REVIEW THIS SECTION AND REVISE ALL |
| | THE TRUSS PACKAGE AS REQUIRED. NOTE: THERE IS AN |
| | ENGINEER OF RECORD ON THIS PROJECT. |
| | |
| | C) THE TRUSS PACKAGE NEEDS TO BE REVIEWED AND APPROVED |
| | BY THE ENGINEER OF RECORD AS REQUIRED BY SEC. |
| | 61G15-31.003. NOTE: J.A.O IS NOT THE ENGINEER OF |
| | RECORD. |
| | |
| | |
| | 10- SHEET S-2: |
| | A) ENGINEER OF RECORD TO REVISE ALL THE SIMPSON |
| | CONNECTORS THAT DON'T MEET THE UPLIFT CALCULATIONS AS |
| | SHOWN ON THE TRUSS PACKAGE. COORDINATE WITH THE TRUSS |
| | PACKAGE AND REVISE AS REQUIRED. SEC. 107.2.1 CITY |
| | AMENDMENTS TO FBC. |
| | |
| | B) SIMPSON CONNECTOR LTA1 WAS DISCONTINUED BY SIMPSON. |
| | SPECIFY CURRENT CONNECTOR. SEC. 107.2.1 CITY AMENDMENTS |
| | TO FBC. |
| | |
| | 11- THE CERTIFICATE OF AUTHORIZATION (#8495) FOR |
| | "DESIGN ENGINEERING & SUPPLY" ENGINEER FIRM NEEDS TO BE |
| | UPDATED. ENGINEER TO CONTACT DBPR AND UPDATE AS |
| | REQUIRED BY SEC. 61G15-23.002. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561)805-6712 |