| 2013-06-03 15:59:27 | BUILDING PLAN REVIEW |
| | PERMIT: 13040011 |
| | ADD: 1002 GREEN PINE BLVD # B1 |
| | CONT: H LAYTON MAINGUY GC |
| | TEL: (954)249-8500 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: 6/03/ 2013 |
| | ACTION: PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1) THE PRODUCT APPROVAL SUBMITTED FOR THE HORIZONTAL |
| | SLIDERS DOES NOT INCLUDE MULLIONS WINDOW TYPE D |
| | INDICATES THERE ARE TWO ADJOINING WINDOWS THAT WILL |
| | REQUIRE EITHER A MULLION OR A STRUCTURAL FRAMING MEMBER |
| | TO TRANSFER THE WINDOW LOADS IN TO THE EXTERIOR WALL |
| | SYSTEM, PART OF THE MWFRS, PLEASE SHOW COMPLIANCE WITH: |
| | MULLIONS OR MULLED FENESTRATION ASSEMBLIES SHALL BE |
| | TESTED BY AN APPROVED TESTING LABORATORY IN ACCORDANCE |
| | WITH EITHER AAMA 450, ASTM E 330, OR TAS 202 (HVHZ |
| | SHALL COMPLY WITH TAS 202), OR SHALL BE ENGINEERED IN |
| | ACCORDANCE WITH AAMA 450 USING ACCEPTED ENGINEERING |
| | PRACTICE. MULLIONS TESTED AS STAND-ALONE UNITS OR |
| | QUALIFIED BY ENGINEERING SHALL USE PERFORMANCE CRITERIA |
| | CITED IN SECTIONS 1715.5.5.2, 1715.5.5.3 AND |
| | 1715.5.5.4. MULLIONS QUALIFIED BY AN ACTUAL TEST OF AN |
| | ENTIRE ASSEMBLY SHALL COMPLY WITH SECTION 1715.5.5.4, |
| | EXCEPT THAT MULLIONS IN ASSEMBLIES REQUIRING A |
| | DEFLECTION LIMITATION, AS DEFINED IN AAMA/WDMA/CSA |
| | 101/I.S.2/A440, SHALL MEET 1715.5.5.2 AND 1715.5.5.3. |
| | PRODUCTS NOT INCLUDED WITHIN THE SCOPE OF SECTION |
| | 1715.5.5.1 SHALL COMPLY WITH SECTIONS 1715.5.5.3 AND |
| | 1715.5.5.4. |
| | 1715.5.5.2 LOAD TRANSFER. |
| | 1715.5.5.3 DEFLECTION. |
| | 1715.5.5.4 STRUCTURAL SAFETY FACTOR. |
| | 1715.5.5.4 STRUCTURAL SAFETY FACTOR. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |