Plan Review Notes
Plan Review Notes For Permit 13030811
Permit Number 13030811
Review Stop B
Sequence Number 1
Notes
Date Text
2013-04-15 07:57:28BUILDING PLAN REVIEW
 PERMIT: 13030811
 ADD: 4001 S DIXIE HWY
 CONT: TBD
 TEL: (727)216-6354
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: 4/15/2013
 ACTION: DENIED
  
 1) COVERSHEET G-010:,
  
 1A) THE STRUCTURE WAS DESIGNED TO THE 2007 FBC FAMILY
 OF CODES, AS OF MARCH 15 2012 THE 2010 FBC WAS ADOPTED
 STATEWIDE.
  
 1B) THE WIND DESIGN CRITERIA PRESSURES STATE THEY ARE
 ASCE 7-05 WHERE AS THE WIND DESIGN SHOULD BE UNDER ASCE
 7-10/ 2010 FBC-B. IT IS NOTED THAT THE WIND DEISN FOUND
 ON S-320 ARE ASCE -7-10 V-ULT BUT THE EXPOSURE IS
 INDICATED A "B" EXPOSURE PLEASE REVIEW SECTION 2010
 FBC-B SURFACE ROUGHNESS C. 1609.4.2 SURFACE ROUGHNESS
 CATEGORIES.
 THIS CATEGORY INCLUDES FLAT OPEN COUNTRY AND
 GRASSLANDS.THIS SURFACE ROUGHNESS SHALL ALSO APPLY TO
 ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS B-TYPE
 TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET
 HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE
 ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN
 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET IN
 THE UPWIND DIRECTION. SHORT-TERM (LESS THAN TWO YEAR)
 CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,...
 THIS CATEGORY INCLUDES FLAT OPEN COUNTRY AND GRASSLANDS
 AND SHALL EXTEND DOWNWIND FOR A DISTANCE OF 1500 FEET
 THIS WILL AFFECT THE PRRESSURES OF THE WALL AND ROOF
 PRESSURES FOR ALL ZONES.
  
 2) ON THE FOLLOWING SHEETS WEILDING INFORMATION AS TO
 WIDTH AND LENGTH OF WELD HAS BEEN LEFT OFF THE SHEET:
 S110 DETAIL 5, S-310 DETAIL # 8, S-330 DETAIL # 4 &
 S340 DETAIL #9.
  
 3) SHEET S-210 WALL SECTION 6 INCH METAL STUD DOES NOT
 PROVIDE HOW IT WILL BE ATTACHED TO THE BOTTOM CHORD OF
 THE TRUSS.
  
 4) SHEET S-220 & S-230 THE PLANS DO NOT STATE HOW THE
 STEEL ANGLES WILL BE ATTACHED TO THE STRUCTURAL STEEL
 OR HOW THE 16 GA. CLIPS WILL BE ATTACHED TO THE STEEL
 ANGLES?
  
 5) THIS PROJECT WILL REQUIRE A RESIDENT INSPECTOR. 2010
 FBC* 110.3.9 RESIDENT INSPECTOR. SUBMIT INSPECTOR
 RESUME' AND LICENSE
 DOCUMENTS TO KEN CONRAD, DIRECTOR OF THE RESIDENT
 INSPECTOR PROGRAM. A RESIDENT INSPECTOR PROGRAM IS
 REQUIRED, ON THIS PROJECT, DUE TO ONE OR MORE OF THE
 FOLLOWING:
 - BUILDINGS/ADDITIONS OF TYPE I OR II CONSTRUCTION
 - ANY MAJOR STRUCTURAL ALTERATIONS
 - STRUCTURES IN WHICH THE CONCRETE DESIGN IS BASED ON
 COMPRESSIVE STRENGTH (F'C) IN EXCESS OF 3000 PSI
 - PILE DRIVING
 - BUILDINGS OVER 20,000 SQ FT IN AREA
 - BUILDINGS OVER 2 STORIES IN HEIGHT
 - BUILDING/STRUCTURES OF UNUSUAL DESIGN OR METHODS OF
 CONSTRUCTION
 KEN CONRADS CONTACT INFORMATION:
 TEL: (561)805-6666
 E-MAIL: KCONRAD @WPB.ORG
  
 6) THREE SETS OF PLANS AND PRODUCT APPROVALS WILL BE
 REQUIRED, A THIRD SET OF PLANS WILL BE REQUIRED FOR THE
 ON-SITE RESIDENT INSPECTOR.
  
 7) WITH THE PROJECT BEING DESIGNED AS A EXPOSURE B THE
 PRESSURES WILL INCREASE BEING LOCATED WITHIN A "C"
 EXPOSURE. FOR THE PRODUCT APPROVALS THAT DEAL WITH
 GLAZINGPLEASE CIRCLE WHICH SYTEM WILL BE INSTALLED IN
 THIS PROJECT, PLEASE CIRCLE THE TYPE OF GLAZING, AND IF
 MULLIONS ARE REQUIRED PLEASE CIRCLE THE APPROPRIATE IF
 RE-INFORCED OR NON-REINFORCED. THEN THE APPROPRIATE
 PRESSURES CAN BE
 DETERMINED UNTIL THEN NO REVIEW CAN TAKE PLACE ON THESE
 ASSEMBLIES. 1609. 5.4.4.1.COMPONENTS AND CLADDING.
  
 8) ROOFING PRODUCT APPROVALS, IN EACH OF THESE
 APPROVALS THERE ARE SEVERAL SUB-SYSTEMS WITH VARYING
 PRESSURES, PLEASE CIRCLE WHICH SUB-SYSTEM WHICH WILL BE
 INSTALLED ON THIS PROJECT, VERIFY PRESSURES FOR ZONE 1,
 PLEASE NOTE IF THIS APPROVAL WILL ALLOW ENHANCED
 FASTENING OR NOT. IF ENHANCED FASTENING IS ALLOWED BY A
 DESIGN PROFESSIONAL PLEASE PROVIDE CALCULATION FOR RAS
 117 FOR FLAT DECKS.
 2010 FBC-B 1609.5.2.
  
 9) FOR THE CAPRI CONCRETE ROOF TILE NOA 12-0904.07
 CIRCLE WHICH TYPE OF FASTENER WILL BE USED TO SECURE
 THE ROOF TILE TO THE DECK BELOW. 2010 FBC-B 1609.5.3.
  
 10) THE PLANS NOR THE ROOFING PRODUCT APPROVAL NOA #
 12-0904.07 INDICATE THE FASTENING OF THE RIDGE TILE
 PLEASE PROVIDE CODE COMPLIANCE WITH 1507.3.7 AND
 FRSA/TRI 07320//8-05.
  
 11) UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS
 WHICH COMBINE TO FORM 'THE SITE'. A 'UNITY OF TITLE'
 SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A COPY OF THE
 RECORDED 'UNITY OF OF TITLE' DOCUMENT SO THAT FBC TABLE
 601 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
 SEE WEBSITE FOR APPLICATION:
 HTTP://WWW.WPB.ORG/ENGINEERING/ENG_FORMS.PHP
 "APPLICATION FOR UNITY OF TITLE"
  
 HTTP://WWW.WPB.ORG/ENGINEERING/UPLOADS/2010-10-12-14-45
 -38-UNITYOFTITLE3.PDF
  
 VINCENT J NOEL
 SURVEYOR/REAL ESTATE SUPERVISOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494-1040 EXT: 1096
 FAX: 494-1116
 E-MAIL: [email protected]
  
 *********************************************
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved