2013-05-18 16:37:262026 PONCE DELEON AVENUE
 PERMIT #13030498
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 **NOTE: THIS IS A CHANGE OF OCCUPANCY FROM RESIDENTIAL
 TO COMMERCIAL (BUSINESS).**
  
 RESPONSE COMMENT: SECTION 38.3.2.1 OF NFPA 101, THE
 LIFE SAFETY CODE, REQUIRES A HAZARD SEPARATION OF
 1-HOUR FIRE RESISTANCE. THE HAZARD SEPARATION IS
 DIFFERENT FROM AN OCCUPANCY SEPARATION (FBC 508.4)
 INDICATED IN THE ARCHITECTURAL RESPONSE LETTER.
 ORIGINAL COMMENT: ANY AREA (STORAGE) HAVING A DEGREE OF
 HAZARD GREATER THAN NORMAL TO THE GENERAL OCCUPANCY
 (BUSINESS) OF THE BUILDING, SHALL BE SEPARATED FROM
 NON-STORAGE AREAS WITH A 1-HOUR FIRE-RATED BARRIER OR
 BE PROTECTED WITH AN AUTOMATIC SPRINKLER SYSTEM. DOORS
 SHALL BE SELF CLOSING, POSITIVE LATCHING, AND
 FIRE-RATED FOR AT LEAST 45-MINUTES PER SECTION 8.7 OF
 NFPA 101.
  
 REPEAT COMMENT - STORAGE ROOM: EACH FIRE RATED BARRIER
 SHALL BE PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING READING FIRE BARRIER-PROTECT ALL OPENINGS.
 CHARACTERS SHALL BE AT LEAST 4-INCHES IN HEIGHT AND
 HALF-INCH IN WIDTH. REFERENCE SECTION 8.3.2.4 OF
 FLORIDA FIRE PREVENTION CODE - NFPA 101
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730