| 2013-04-16 16:48:45 | BUILDING PLAN REVIEW |
| | PERMIT: 13030468 |
| | ADD: 501 FERN ST |
| | CONT: TBD |
| | TEL: (561)670-0411 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: 4/16/2013 |
| | ACTION: BUILDING PROVISO |
| | BUILDING APPROVED WITH EXCEPTION! |
| | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO |
| | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO |
| | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE |
| | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE |
| | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. |
| | |
| | 1A) MIAMI-DADE NOA 09-0115.04 GAF EVERGUARDTPO SINGLE |
| | PLY ROOFING SYSTEM OVER STEEL DECK. CONTRACTOR HAS NOT |
| | IDENTIFIED WHICH SUB-SYSTEM IS TO BE INSTALLED, WILL |
| | NEED TO IDENTIFY WHICH SUB-SYSTEM WILL BE INSTALLED. |
| | PLEASE REVIEW THE MAXIMUM DESIGN PRESSURE AND |
| | LIMITATION FOR EACH SUB-SYSTEM. IF LIMITATION # 7 IS |
| | INDICATED, THEN ENHANCED FASTENING WILL BE REQUIRED BY |
| | A DESIGN PROFESSIONAL, RAS 117 CALCULATIONS REQUIRED. |
| | THIS REVIEW WILL REQUIRE A REVISION, WITH ASSOCAITED |
| | FEES. |
| | |
| | 1B) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 2A ) THE ONLY PRODUCT APPROVAL SUBMITTED FOR WALL |
| | OPENINGS WAS EURO-WALL +70/-70 PSF LARGE MISSILE |
| | IMPACT. |
| | ALL OTHER OPENING APPROVALS WILL REQUIRE A REVISION |
| | WITH ASSOCIATED FEES. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | 2B) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |