| Plan Review Notes For Permit 13030161 |
| Permit Number |
13030161 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2013-04-18 10:38:29 | FBC 2010 EXISTING BUILDING CODE | | | FBC 2010 ACCESSIBILITY CODE | | | FBC 2010 PLUMBING REVIEW #2 | | | DENIED: | | | | | | COMMENT FOR REVIEW #1 NOTED. THE EXCEPTION FOR THE | | | BUSINESS DOES APPLY, HOWEVER, THE WAREHOUSE AREA WOULD | | | BE REQUIRED TO HAVE A RESTROOM PER TABLE 403.1 OR 2 | | | RESTROOMS FOR THE TOTAL OCCUPANCY. | | | FBC PLUMBING 403.2 SEPARATE FACILITIES ARE REQUIRED FOR | | | EACH SEX, WITH THE EXCEPTION (3) SEPARATE FACILITIES | | | SHALL NOT BE REQUIRED IN BUSINESS AND MERCANTILE | | | OCCUPANCIES WITH A TOTAL FLOOR AREA OF 3,000 SQUARE | | | FEET (279 M2) OR LESS. | | | SHEET SP 2 LISTS THE OCCUPANCY AS BUSINESS WITH UNDER | | | 3000 S.F. AND THE WAREHOUSE 3301 S.F. WITH THE TOTAL | | | OCCUPANT LOAD AS 34. TOTAL RESTROOMS REQUIRED IS 2. | | | TABLE P403.1 WAREHOUSE (STORAGE) = 1 PER 100 OCCUPANTS. | | | BUSINESS UNDER 3000 S.F. 1 RESTROOM REQUIRED. | | | | | | REVIEW BY | | | LARRY WAGNER | | | CHIEF PLUMBING INSPECTOR | | | PHONE # 805-6692 | | | EMAIL [email protected] | | | FAX # 805-6676 |
|