| 2013-03-19 13:37:38 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. FBC 107.2.1, ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | 2. PLANS TO INCLUDE WIND DESIGN CRITERIA FBC R 301 | | | (WIND SPEED, EXPOSURE CLASSIFICATION). | | | | | | 3. PLANS SPECIFY "TR TD." THIS IS NOT A STANDARD | | | CONSTRUCTION ABBREVIATION. PLANS TO BE SPECIFIC AS TO | | | MATERIAL AND METHODS OF CONSTRUCTION, PLEASE REVISE. | | | FBC 107.2.1. | | | | | | 4. PLANS SPECIFY HURRICANE STRAPS; SPECIFY WHICH STRAP | | | IS PROPOSED. | | | | | | 5. FOUNDATION PLAN NOT CLEAR, GRAPHICALLY DIFFERENT | | | SIZES ARE SHOWN, REFERS TO A "MIDWAY PONY WALL," DOES | | | NOT SPECIFY WHICH JOIST HANGERS PROPOSED. PROVIDE A | | | STRUCTURAL DETAIL, SEE FBC 107.2.1: CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. |
|