Plan Review Notes
Plan Review Notes For Permit 13020827
Permit Number 13020827
Review Stop B
Sequence Number 1
Notes
Date Text
2013-02-28 10:50:47****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. SEE SHEET 31 OF THE NOA. THE ASSEMBLY SELECTED
 REFERS TO GENERAL LIMITATION #9, NO ENHANCED FASTENING
 ALLOWED. PLEASE SELECT ANOTHER ASSEMBLY WHICH EITHER
 MEETS MINIMUM DESIGN PRESSURES FOR ZONES 2/3 OR REFERS
 TO GENERAL LIMITATION #7, SEE SHEET 38.
  
 2. ENHANCE FASTENING TO BE IN ACCORDANCE WITH RAS 117
 AND TO BE DONE BY AN ARCHITECT, ENGINEER, OR REGISTERED
 ROOF CONSULTANT, SEE GENERAL LIMITATION #7 OF THE NOA.
  
 3. INDICATE METHOD OF ATTACHMENT FOR THE TILE, FBC R
 301. IF AN ADHESIVE IS PROPOSED, PROVIDE PRODUCT
 APPROVAL.
  
 4. PROVIDE A COPY OF A VERIFIABLE CONTRACT FOR THIS
 JOB, FBC 109.
  
  