Plan Review Notes
Plan Review Notes For Permit 13020666
Permit Number 13020666
Review Stop B
Sequence Number 1
Notes
Date Text
2013-02-25 16:34:29****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. REVISE FLOOR PLAN TO INCLUDE EXISTING CONDITIONS
 (TYPE OF WINDOW) AND OPENING SIZE FOR BEDROOMS, FBC
 R310, FBC EB 604.1. THE CLEAR OPENING CANNOT BE REDUCED
 BY MORE THAN 5%. NOTE THAT AWNING WINDOWS MAY HAVE AN
 EMERGENCY ESCAPE PANEL.
  
 2. IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R
 301.2.1.2. PROVIDE PRODUCT APPROVALS AND, IF SHUTTERS
 ARE USED, COMPLETE THE SAMPLE INSTALLATION SCHEDULE
 (AVAILABLE IN THE LOBBY AND AT HTTP://WWW.CITYOFWPB.COM
 /CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION.PDF). IF
 SHUTTERS ARE INCLUDED IN THE SCOPE OF THIS PERMIT,
 INCLUDE VALUE INCREASE.
  
  
  