Plan Review Notes
Plan Review Notes For Permit 13020612
Permit Number 13020612
Review Stop FIRE
Sequence Number 2
Notes
Date Text
2013-04-18 09:53:263620 SOUTH DIXIE HIGHWAY
 PERMIT #13020612
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 *****PROVISO - SUBMIT REVISION PROVIDING THE FOLLOWING
 INFORMATION*****
  
 REPEAT COMMENT: THE ADDRESS OF 3260 SOUTH DIXIE IS
 SHOWN ON THE PERMIT APPLICATION; HOWEVER, THIS LOCATION
 APPEARS TO BE 3620 SOUTH DIXIE HIGHWAY.
  
 REPEAT COMMENT: SMOKING SHALL BE PROHIBITED EXCEPT IN
 DESIGNATED EXTERIOR AREAS. ALL OTHER DEMOLITION OR
 CONSTRUCTION AREAS SHALL HAVE WEATHERPROOF "NO SMOKING"
 SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 REPEAT COMMENT: COMMERCIAL SPACE: PROVIDE PORTABLE FIRE
 EXTINGUISHERS. EXTINGUISHERS SHALL HAVE A MINIMUM
 RATING OF 2A:10BC AND SHALL BE TAGGED BY A LICENSED
 FIRE EXTINGUISHER COMPANY. TRAVEL DISTANCE TO
 EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 RESPONSE COMMENT: IF THE WALL HAS A FIRE RESISTANCE
 RATING OF 2-HOURS, THEN THE DOOR OPENING TO BE
 PROTECTED NEEDS TO BE RATED FOR 90 MINUTES. TO INSTALL
 A 45-MINUTE RATED DOOR BECAUSE THE WALL IS OVERDESIGNED
 AS 2-HOURS IN LIEU OF 1-HOUR WILL BE VERY CONFUSING
 DURING INSPECTIONS.
 ORIGINAL COMMENT:SHEET A-1UA: DOORS SUCH AS #9 SHOULD
 HAVE A FIRE RESISTANCE RATING OF 90 MINUTES WHEN
 LOCATED WITHIN A 2-HOUR FIRE BARRIER.
  
 REVIEW #2 - NEW COMMENTS:
 SHEET FP-2: PROVIDE A SIAMESE FIRE DEPARTMENT
 CONNECTION WITH LOCKING KNOX CAPS.
  
 WESLEY JOLIN
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730