| 2013-03-22 09:49:49 | BUILDING PLAN REVIEW |
| | REVISION: 13020592 |
| | PERMIT: 13020066 |
| | ADD: 5600 N FLAGLER DR #2402 |
| | CONT: PEDRO FURTADO |
| | TEL: (561)290-3844 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: 3/22/2013 |
| | ACTION: DENIED |
| | |
| | 1) CONTRACTOR TO TAKE OWNERSHIP OF THEIR OWN PLANS, |
| | PLEASE PRINT YOUR NAME, SIGN YOUR NAME AND PRINT YOUR |
| | LICENSE NUMBER ON EACH PLAN YOU ARE THE AUTHOR OF, |
| | PLEASE NOTE YOU CAN ONLY DRAW PLANS FOR WHICH YOU ARE |
| | LICENSED. A CGC CAN DRAW THE FLOOR PLAN, BUT NOT |
| | ELECTRICAL OR PLUMBING. 107.1. |
| | |
| | 2) THE RED TAG WRITTEN INDICATES FLOORING TO BE PART OF |
| | THIS REVISION. THE PLANS NOR REDTAG PROVIDE WHAT TYPE |
| | OF FLOORING IS BEING APPLIED OR WHERE. NOTE THIS |
| | BUILDING IS A HIGH RISE AND MUST COMPLY WITH TWO |
| | DIFFERENT CODE SECTIONS: |
| | |
| | 2A) 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | 2B) 03.1 ALLOWABLE MATERIALS. |
| | COMBUSTIBLE MATERIALS SHALL BE PERMITTED IN BUILDINGS |
| | OF TYPE I OR II CONSTRUCTION IN THE FOLLOWING |
| | APPLICATIONS AND IN ACCORDANCE WITH SECTIONS 603.1.1 |
| | THROUGH 603.1.3: |
| | 2.EXCEPTIONS: 1. INSULATION PLACED BETWEEN TWO LAYERS |
| | OF NONCOMBUSTIBLE MATERIALS WITHOUT AN INTERVENING |
| | AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX |
| | OF NOT MORE THAN 100. THIS REQUIREMENT IS FLOOR TILE |
| | TYPE FLOORS, MABLE AND OR STONE THAT REQUIRES |
| | INSULATION BETWEEN THE NONCOMBUSTIBLE LAYERS. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |