| Date |
Text |
| 2013-02-27 12:34:17 | 6610 NORTH JOG ROAD |
| | PERMIT #13020323 |
| | REVIEW COMMENTS - FIRE DEPARTMENT |
| | |
| | PROVIDE A LETTER OR NUMBER ON EACH CONSTRUCTION TRAILER |
| | TO ALLOW EMERGENCY RESPONDERS TO PROVIDE QUICK RESPONSE |
| | TO THE APPROPRIATE LOCATION. LETTERS OR NUMBERS SHALL |
| | BE ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES |
| | IN HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE |
| | BACKGROUND. |
| | |
| | PROVIDE STAIRS OR RAMP FOR ACCESS INTO THE TRAILERS. |
| | STAIR RISERS SHALL BE BETWEEN 4 INCHES AND 7 INCHES IN |
| | HEIGHT. STAIRS SHALL BE SLIP RESISTANT AND HAVE A |
| | MINIMUM TREAD DEPTH OF 11 INCHES AND PREVENT THE |
| | ACCUMULATION OF WATER. |
| | |
| | HANDRAILS ARE REQUIRED ON BOTH SIDES OF THE STAIR. |
| | HANDRAILS SHALL BE LOCATED NOT LESS THAN 34 INCHES AND |
| | NOT MORE THAN 38 INCHES ABOVE THE SURFACE OF THE TREAD, |
| | MEASURED VERTICALLY TO THE TOP OF THE RAIL FROM THE |
| | LEADING EDGE OF THE TREAD. HANDRAIL ENDS SHALL BE |
| | RETURNED TO THE WALL OR FLOOR OR SHALL TERMINATE AT |
| | NEWEL POSTS. HANDRAIL CROSS SECTION SHALL HAVE A |
| | DIAMETER OF NOT LESS THAN 1.25 INCHES AND NOT MORE THAN |
| | 2 INCHES. |
| | |
| | GUARDS, AT LEAST 42-INCHES TALL, SHALL BE PROVIDED AT |
| | THE OPEN SIDES OF STAIRS THAT EXCEED 30-INCHES ABOVE |
| | THE FLOOR. OPEN GUARDS SHALL PROHIBIT THE PASSAGE OF A |
| | 4-INCH DIAMETER SPHERE UP TO A HEIGHT OF 34-INCHES. THE |
| | TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND |
| | BOTTOM ELEMENT OF THE GUARDRAIL SHALL PROHIBIT THE |
| | PASSAGE OF A 6-INCH DIAMETER SPHERE. |
| | |
| | WESLEY JOLIN |
| | FIRE INVESTIGATOR & INSPECTOR |
| | OFFICE OF THE FIRE MARSHAL |
| | WEST PALM BEACH FIRE RESCUE |
| | [email protected] |
| | (561) 805-6730 |
| | |