| Plan Review Notes For Permit 13020303 |
| Permit Number |
13020303 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-03-20 11:43:50 | 2010 FBC | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF A SURVEY SHOWING THE LOCATIONS | | | OF THE STRUCTURES ON THE LOT. CITY AMENDMENTS 107.2.1 | | | | | | 2) THE DWELLING UNIT SEPARATION WALL SHALL COMPLY WITH | | | FBC R302.3. THE ONE HOUR FIRE RESISTIVE WALL SHALL | | | EXTEND FROM THE FOUNDATION TO THE UNDERSIDE OF THE ROOF | | | SHEATHING. ALSO SEE THE EXCEPTIONS. | | | | | | 3) THE PRODUCT APPROVAL FOR THE STRUCTURAL MULLIONS NOA | | | NO. 10-0510.14 HAS BEEN SUPERSEDED. SUBMIT TWO COPIES | | | OF THE CURRENT PRODUCT APPROVALS FOR THE STRUCTURAL | | | MULLIONS. DCA RULE 9N-3 | | | | | | 4) THE INSTALLATION INSTRUCTIONS FOR THE EXTERIOR | | | FIBERGLASS DOOR ARE INCOMPLETE. HALF OF EACH SHEET IS | | | MISSING. THE DRAWINGS WILL NEED TO BE SHRUNK TO FIT ON | | | THE 8.5" X 11" PAPER. PLEASE SUBMIT COMPLETE DRAWINGS. | | | DCA RULE 9N-3 | | | | | | 5) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | | THE PROJECT. CITY AMENDMENTS 107.3.4.1 | | | | | | 6) BASED ON INFORMATION OBTAINED FROM THE PALM BEACH | | | COUNTY PROPERTY APPRAISER, IT APPEARS THAT THIS | | | STRUCTURE IS AN EXISTING SINGLE FAMILY DWELLING. THE | | | PROPOSED RENOVATION IS TO CONVERT IT TO A TWO FAMILY | | | DWELLING AND CONVERT EXISTING STORAGE TO LIVING SPACE. | | | THEREFORE, THE APPROVED PLANS WILL NEED TO BE REVIEWED | | | BY PALM BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES | | | ARE DUE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|