| 2013-02-07 16:34:45 | BUILDING PLAN REVIEW |
| | PERMIT: 13010847 |
| | ADD: 550 S ROSEMARY # 158 |
| | CONT: GREATER BAY INC |
| | TEL: (813)267-7391 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | FEB. 07/2013 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE CORRECT THE ADDRESS ON THE PLANS TO 550 S |
| | ROSEMARY # 158 ON BOTH THE PLANS AND ENERGY |
| | CALCULATIONS. |
| | |
| | 2) PLEASE CORRECT THE MINIMUM TYPE CONSTRUCTION, THIS |
| | BUILDING WAS BUILT UNDER THE 1994 SSBC CODE AS A TYPE |
| | II UNDER THE 2010 FBCTHE COMPARISON IS A TYPE I-B. |
| | PLEASE CORRECT ALL SHEETS THAT INDICATE THE 1994 SSBC |
| | TYPE II. |
| | |
| | 3) SHEET A0.1 WINDICATES THE WIND DESIGN AS A 170 MPH |
| | ZONE BUT DOES NOT PROVIDE THE EXPOSURE TYPE NOR DOES |
| | THE PLANS PROVIDE PRESSURES POSITIVE/ NEGATIVE. |
| | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | 3.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| | |
| | 3.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| | |
| | 3.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| | |
| | 3.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | 3.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| | TABLE 1609.2(2) . |
| | |
| | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP. |
| | |
| | 5) THE FLORIDA PRODUCT APPROVAL SUBMITTED FL 13407.R2 |
| | SHEET 2 OF 10 PROVIDES TWO DESIN PRESSURES, ONE THAT IS |
| | FLUSH WITH SILL AND THE OTHER IS NOT, WHICH UNIT IS TO |
| | BE INSTALLED, THE PRESSURES ARE DIFFERENT. 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 6) THE DOOR SCHEDULE IS FOUND ON A.01 DOOR # 6 IS A |
| | FIRE RATED DOOR THAT LEADS INTO A EXIT PASSAGE WAY, NO |
| | FIRE RATING HAS BEEN PROVIDED. 2010 FBC-B TABLE 715.4. |
| | |
| | 7) SHEET A.02 PROVIDES DETAILS FOR FIRE RATED WALLS, |
| | BUT THE DETAILS DO NOT PROVIDE THE REQUIRED FIRE RATING |
| | FOR THE STRUCTURAL COLUMNS SEE 2010 FBC-B TABLE 601 |
| | PRIMARY FRAMING MEMBERS 2 HR FOR TYPE IB. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |