| Date |
Text |
| 2013-05-23 09:33:42 | BUILDING PLAN REVIEW |
| | PERMIT: 13010628 |
| | ADD: 2471 OKEECHOBEE BLVD |
| | CONT: TBD/ PARKWAY CONSTRUCTION |
| | TEL: (469)322-3758 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | MAY 30/2013 |
| | ACTION: |
| | |
| | |
| | |
| | 1) COMPLIED. ADDRESS 2471 OKEECHOBEE BLVD SUITE "A". |
| | |
| | 2) COMPLIED. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) COMPLIED. |
| | |
| | 5) COMPLIED. |
| | |
| | 6) 3RD REQUEST SHEET A-0.1 & A1.0 BOTH INDICATE THE NEW |
| | GUARD RAIL BUT THE PLANS FAIL TO PROVIDE DETAILS FOR |
| | THE HANDRAIL REQUIREMENT PER 2010 ACCESSIBILITY CODE |
| | 405.8. BOTH SIDES OF THE RAMP! |
| | |
| | 7) SHEET A-3.1 & A-7.1: |
| | 7A1) 3RD REQUEST. THE PLANS INDICATE A NEW ROOF HATCH, |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:(31)(A) |
| | ACCESS HATCHES. A INFORMATION SHEET ON BILCO HATCH WAS |
| | SUBMITTED AND A PRODUCT APPROVAL NUMBER NOA 11-0722.10 |
| | IS REFERENCED NO PRODUCT APPROVAL WAS SUBMITTED. I |
| | PRINTED OUT THE MIAMI-DADE NOA THE PRESSURES FOR THIS |
| | PRODUCT ARE =/- 70 PSF. SHEET A-4.0 THE REAR ELEVATION |
| | INDICATES THERE IS NO REAR PARAPET WHICH CREATES A ROOF |
| | ZONE 3, THE LOCATION OF THE ROOF HATCH IS LOCATED IN |
| | THE ROOF ZONE 3 WITH THE -96.96 PRESSURES WHICH EXCEEDS |
| | THE PRESSURES FOR THE PRODUCT APPROVAL. |
| | |
| | 7A)(2) 2RD REQUEST, PLEASE ALSO REVIEW GUARDS 1013.6 |
| | AND 1013.5. THE LITERATURE SUBMITTED WAS NOT LEGIBLE, |
| | DID NOT PROVIDE WHAT THE HEIGHT OF THIS GAURDRAIL. |
| | GAURDS MUST ALSO MEET THE STRENGTH REQUIREMENTS OF |
| | 1607.1.1. THIS CAN BE A ITEM LISTED WITH A PROVISO: |
| | SHOP DRAWINGS TO FOLLOW MEETING THESE CONDITIONS. |
| | |
| | 7B) SEMI-COMPLIED. THE RESPONCE DOES PROVIDE DETAILS ON |
| | RAISED CURB DETAILS THAT WERE TESTED TO THE MIAMI-DADE |
| | PROTOCAL, BUT THE ACTUAL MIAMI-DADE PRODUCT APPROVALS |
| | HAVE NOT BEEN PROVIDED, THERE ARE (6) LISTED FOR THYBAR |
| | ROOF CURBS. A-7.1 & M1.3 BOTH INDICATE A DETAIL FOR |
| | RAISED CURBS, PLEASE PROVIDE THE PRODUCT APPROVAL FOR |
| | THE NEW CURB THAT IS BEING INSTALLED FOR A/C UNIT #4. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | 7C) COMPLIED. |
| | |
| | 7D)COMPLIED. |
| | |
| | 7E) 3RD REQUEST. WE PRINTED OUT THE FL 14209 REPORT IT |
| | IS FOR THE 2007 FBC NOT THE CURRENT 2010 FBC, WE ALSO |
| | CHECKED THE MIAMI-DADE SITE FOR PRODUCT LISTED UNDER |
| | PRECISION ALIMINUM PRODUCTS AND THERE WERE NO CURRENT |
| | REPORTS LISTED ON EITHER WEB-SITE. A/C STANDS FOR ROOF |
| | TOP CONDENSORS. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: (31)((G) PRE-ENGINEERED A/C STANDS. |
| | |
| | 7F) COMPLIED. PRINTED THE PRODUCT APPROVAL FOR JMB PIPE |
| | PROP ADJUSTABLE PVC PIPE STAND NOA 11-1019.05. |
| | |
| | 8A) 3RD REQUEST , A ROOFING PERMIT WILL BE REQUIRED FOR |
| | ALL ROOF REPAIRS FOR THE NEW OPENINGS WITHIN THE ROOF |
| | AND CURBS THAT ARE BEING INSTALLED. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: FLAT DECK RESPONCE |
| | INDICATES A PRODUCT APPROVAL FL # 10124.1 WHICH IS FOR |
| | GAF ASPHALT ROOF SHINLES, THIS ROOF IS A FLAT DECK, |
| | SHINGLES CAN'T BE USED WHEN SLOPES ARE LESS THAN 2:12. |
| | |
| | 8B) AWNING DETAILS METAL ROOFS, RESPONCE INDICATES AN |
| | ENGINEERED AWNING SYSTEM. IF THESE ARE TO BE CONSIDERED |
| | AWNINGS, THEY ARE UNDER SEPERATE PERMIT, THE |
| | ENGINEERING WILL NEED TO BE ORIGINAL SIGNED AND SEALED |
| | DRAWINGS. PLEASE ALSO SUBTRACT THE AMOUNT OF THE |
| | AWNINGS OUT OF THIS PERMIT SO IT WILL BE APPLIED TO THE |
| | SEPERATE AWNING PERMIT. PROVISO. |
| | |
| | 9-14) COMPLIED. |
| | |
| | 15) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |