| Date |
Text |
| 2013-03-18 16:55:40 | BUILDING PLAN REVIEW |
| | PERMIT: 13010628 |
| | ADD: 2471 OKEECHOBEE BLVD |
| | CONT: TBD/ PARKWAY CONSTRUCTION |
| | TEL: (469)322-3758 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | MARCH 18/2013 |
| | ACTION: DENIED |
| | |
| | 1)2ND REQUEST, THE ADDRESS PROVIDED ON THE PLANS AS |
| | WELL AS THE PERMIT APPLICATION IS THE SITE ADDRESS FOR |
| | THE WHOLE PARCEL. THIS TENANT EITHER HAS AN INDIVIDUAL |
| | STREET ADDRESS OR A SUITE NUMBER TO IDENTIFY THE |
| | INDIVIDUAL TENANT SPACE FOR INSPECTION PURPOSES, |
| | RECORDS, RECORD RETENSION AS WELL AS EMERGENCIES. 105.3 |
| | ACTION ON APPLICATION WPB AMENDMENTS TO ADMINISTRATIVE |
| | CODE, CHAPTER 1/ 2010 FBC. PLEASE SEE P B COUNTY |
| | PROPERTY APPRAISERS WEB SITE, PUT IN THE PCN |
| | 74-4343-19-08-000-0010 AND THE WHOLE SITE COMES UP WITH |
| | 2471 FOR A SITE ADDRESS. 18.2417 ACRES AND 235501 TOTAL |
| | SQUARE FEET. |
| | |
| | 2) SEMI-COMPLIED, WILL NEED TO CHANGE EITHER THE |
| | ADDRESS OR THE SQUARE FEET OF THE PROJECT, AREA ENTERED |
| | FROM PLANS IS 13,314 SF. CHANGE OF OCCUPANCY FROM |
| | MERCANTILE TO A2 ASSEMBLY, ENERGY CALCULATIONS |
| | REQUIRED, 2010 FBC-ENERGY CODE 913. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) COMPLIED. |
| | |
| | 5) 2ND REQUEST, SEMI COMPLIED. SHEET A-0.1 & S-2.0 BOTH |
| | INDICATE A NEW DOORWAY AND ACCESSIBLE RAMP. PLEASE |
| | REVIEW TTHE 2010 ACCESSIBILITY CODE 405.7.4.RAMPS, |
| | CHANGE IN DIRECTION. THE PLAN DOES NOT INDICATE A |
| | BOTTOM LANDING, IS THERE ENOUGH ROOM? 2010 |
| | ACCESSIBILITY 405.7. |
| | SHEET S-2.0 THE RAMP SHOWS A WIDTH DIMENSION OF 5'-0" |
| | AN OVER ALL DIMENSION CROSS SECTION WAY, THE |
| | ACCESSBILITY CODE REQUIRES A 5'-0" X 5'-0" CLEAR |
| | LANDING 2010 ACCESSIBILITY CODE 405.7.4. |
| | |
| | |
| | |
| | |
| | |
| | 6) 2ND REQUEST SHEET A-0.1 & A1.0 BOTH INDICATE THE NEW |
| | GAURD RAIL BUT THE PLANS FAIL TO PROVIDE DETAILS FOR |
| | THE HANDRAIL PER 2010 ACCESSIBILITY CODE 405.8. |
| | |
| | 7) SHEET A-3.1 & A-7.1: |
| | 7A1) 2ND REQUEST, THE PLANS INDICATE A NEW ROOF HATCH, |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:(31)(A) |
| | ACCESS HATCHES. A INFORMATION SHEET ON BILCO HATCH WAS |
| | SUBMITTED AND A PRODUCT APPROVAL NUMBER NOA 11-0722.10 |
| | IS REFERENCED NO PRODUCT APPROVAL WAS SUBMITTED. |
| | |
| | 7A)(2) 2ND REQUEST, PLEASE ALSO REVIEW GUARDS 1013.6. |
| | |
| | 7B) COMPLIED. A-7.1 & M1.3 BOTH INDICATE A DETAIL FOR |
| | RAISED CURBS, PLEASE PROVIDE THE PRODUCT APPROVAL FOR |
| | THE NEW CURB THAT IS BEING INSTALLED FOR A/C UNIT #4. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES |
| | |
| | 7C) COMPLIED. THE PLANS INDICATE THE EXISTING CURBS ARE |
| | TO HAVE AN ADAPTOR OVER THE EXISTING CURB, PLEASE |
| | PROVIDE THE MANUFACTURERS SPECIFICATIONS .HOW THEY WILL |
| | BE SECURED TO THE EXISTING CURB? 107.2.1.3 ADDITIONAL |
| | INFORMATION IS REQUIRED. |
| | |
| | 7D)COMPLIED. A-7.1 DETAIL # 3 INDICATES THE USE OF WOOD |
| | SLEEPERS AND PITCH PANS, THIS HAS NOT BEEN ALLOWED IN |
| | FLORIDA SINCE THE 2001 FBC. 2010 FBC-B TABLE 1509.7 |
| | PROVIDES THE REQUIRED HEIGHT OF THE UNIT ABOVE THE ROOF |
| | COVERING DEPENDING ON THE WIDTH OF THE UNIT. |
| | |
| | 7E) COMPLIED. A/C STANDS FOR ROOF TOP CONDENSORS. |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: (31)((G) |
| | PRE-ENGINEERED A/C STANDS. |
| | |
| | 7F) 2ND REQUEST ROOF TOP BLOX, AN ENGINEERING LAB TEST |
| | REULTS WERE SUBMITTED IT APPEARS TO BE A SITE SPECIFIC |
| | CASE IN ELLINGTON, MAINE FOR A 150 MPH WIND ZONE. WE DO |
| | ACCESPT NATIONALLY RECONIZED REPORTS FROM THE ICC ER |
| | REPORTS, ERS REPORTS ETC, PLEASE PROVIDE A CURRENT |
| | REPORT FROM A NATIONALLY RECONIZED TESTING AGENCY. THE |
| | REPORT SUBMITTED FOR ROOF TOP BLOX INDICATES THE WIND |
| | TEST WAS FOR 150 MPH, WE ARE LOCATED IN A 170 MPH WIND |
| | ZONE. |
| | |
| | 8) 2ND REQUEST , A ROOFING PERMIT WILL BE REQUIRED FOR |
| | ALL ROOF REPAIRS FOR THE NEW OPENINGS WITHIN THE ROOF |
| | AND CURBS THAT ARE BEING INSTALLED. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES FLAT ROOF |
| | REPAIR AS WELL AS THE METAL FOR THE AWNING DETAIL. |
| | |
| | 9) DISCREPANCY SHEET A4.0 LIST THE EXTERIOR OF THE |
| | BUILDING TO RECEIVE A 3 COAT STUCCO APPLICATION, SHEET |
| | A7.2 DETAIL # 12 INDICATES THE USE OF PAREX AND A |
| | ERS-2564 REPORT WAS SUBMITTED FOR A ONE COAT STUCCO |
| | SYSTEM, WHICH SYSTEM IS CORRECT? |
| | |
| | 10-14) COMPLIED. |
| | |
| | 15) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |
| | |
| | |