| Notes |
| Date |
Text |
| 2013-02-11 11:56:29 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- CEILING ABOVE GARAGE SHALL BE MIN. 5/8" TYPE "X" | | | GYPSUM BOARD. TABLE R302.6. REVISE PLANS AS REQUIRED. | | | 2- BALCONY ELEVATION CALLS FOR NEW WINDOW. FLOOR PLAN | | | CALLS FOR EXISTING WINDOW TO REMAIN. REVISE AS REQUIRED | | | TO MATCH. | | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR ALL STRUCTURAL CONNECTORS SPECIFIED | | | ON NEW STRUCTURAL COLUMN DETAIL ON SHEET A1. PROVIDE | | | ONLY THE PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING | | | THE SPECIFIED CONNECTORS. | | | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC. | | | 5- ENGINEER TO PROVIDE GARAGE BUCK DETAIL DRAWINGS WITH | | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 | | | FLORIDA STATUTE. | | | |
|