Text |
| 2013-01-31 14:16:53 | 2010 FBC |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION SECTION |
| | 401.2 FOR THE NEW BREAKFAST ROOM. |
| | |
| | 2) SHOW COMPLIANCE WITH FBC R314.3.1 FOR SMOKE ALARMS. |
| | |
| | 3) UPDATE GENERAL NOTES ON SHEET CVR TO REFLECT THE |
| | 2010 FBC AND THE REFERENCED STANDARDS IN CHAPTER 43 OF |
| | FBC RESIDENTIAL. ASTM C94-07, ACI - 08 EDITIONS, AND |
| | 2010 FBC FOR #S 40 AND 41. |
| | |
| | 4) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE |
| | EXTERIOR DOORS, WINDOWS, ROOFING MATERIAL, TRUSS |
| | ANCHORS AND CONNECTORS AS REQUIRED BY DCA RULE 9N-3. |
| | |
| | 5) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR |
| | THE PROJECT. CITY AMENDMENTS 107.3.4.1. |
| | |
| | 6) PROVIDE STRUCTURAL DETAILS FOR THE CONSTRUCTION OF |
| | THE ARCH AT THE GABLE OF THE SECOND FLOOR BALCONY. CITY |
| | AMENDMENTS 107.2.1 |
| | |
| | 7) THE PLANS SHOW A FRENCH DOOR AT THE REAR OF THE |
| | BREAKFAST ROOM THAT OPENS OUT OVER THE EXISTING POOL. |
| | INDICATE HOW THIS WILL COMPLY WITH FBCR 311.3 WHICH |
| | REQUIRES A FLOOR OR LANDING ON EACH SIDE OF EACH |
| | EXTERIOR DOOR. |
| | |
| | 8) SHOW COMPLIANCE WITH FBCR 4101.17 FOR RESIDENTIAL |
| | SWIMMING POOL BARRIER REQUIREMENT AT NEW ADDITION. |
| | |
| | 9) THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE WHICH |
| | REQUIRES THE ADDITION TO HAVE A FINISH FLOOR ELEVATION |
| | OF 7'-6" BFE WHICH INCLUDES A 6" FREEBOARD REQUIRED BY |
| | THE CITY'S MUNICIPAL CODE. SPECIFY THE FINISH FLOOR |
| | ELEVATION ON THE PLANS AND PROVIDE AN ELEVATION |
| | CERTIFICATE WITH THE PROPOSED FINISH FLOOR ELEVATION. |
| | FBCR 322 AND CITY FLOOD PLAIN ORDINANCE |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |