Plan Review Notes
Plan Review Notes For Permit 13010327
Permit Number 13010327
Review Stop B
Sequence Number 2
Notes
Date Text
2013-02-26 12:50:44****CORRECTIONS****
 2/13/2013 RESUBMITTAL
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. OK
  
 2. SEE FBC TABLE 602 REGARDING FIRE RESISTANCE
 REQUIREMENTS AND REVISE PLANS TO SHOW COMPLIANCE; BOTH
 DISTANCE TO PROPERTY LINES AS WELL AS DISTANCE TO
 ASSUMED PROPERTY LINE BETWEEN PROPOSED SHED AND
 EXISTING BUILDING. INCLUDE ALL INFORMATION REQUIRED TO
 SHOW CODE COMPLIANCE SUCH AS BUILDING TYPE (FBC CHAPTER
 6), AREA, OCCUPANCY CLASSIFICATION (FBC CHAPTER 3).
  
 2ND REVIEW:
  
 SEE FBC TABLE 602. TYPE IIB STRUCTURE, 3' FROM PROPERTY
 LINE REQUIRES A 2 HOUR RATED WALL. PROVIDE A DETAIL OR
 CHANGE PROPOSED LOCATION.
  
 DISTANCE TO ASSUMED PROPERTY LINE BETWEEN THE TWO
 STRUCTURES ON THE SAME LOT NOT PROVIDED. NO INFORMATION
 REGARDING THE EXISTING BUILDING WAS PROVIDED.
  
 NEW COMMENT:
  
 3. PLEASE PROVIDE AN ARCHITECTURAL DETAIL OF THE FOUR
 SIDES OF THE PROPOSED SHED WHICH INCLUDES OPENINGS
 (DOORS AND/OR WINDOWS) AND ORIENTATION OF THE PROPOSED
 SHED (INDICATE NORTH, SOUTH, EAST, WEST ELEVATIONS).
 SEE FBC TABLE 602, TABLE 705.8.
  