| Plan Review Notes For Permit 13010327 |
| Permit Number |
13010327 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2013-02-26 12:50:44 | ****CORRECTIONS**** | | | 2/13/2013 RESUBMITTAL | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. OK | | | | | | 2. SEE FBC TABLE 602 REGARDING FIRE RESISTANCE | | | REQUIREMENTS AND REVISE PLANS TO SHOW COMPLIANCE; BOTH | | | DISTANCE TO PROPERTY LINES AS WELL AS DISTANCE TO | | | ASSUMED PROPERTY LINE BETWEEN PROPOSED SHED AND | | | EXISTING BUILDING. INCLUDE ALL INFORMATION REQUIRED TO | | | SHOW CODE COMPLIANCE SUCH AS BUILDING TYPE (FBC CHAPTER | | | 6), AREA, OCCUPANCY CLASSIFICATION (FBC CHAPTER 3). | | | | | | 2ND REVIEW: | | | | | | SEE FBC TABLE 602. TYPE IIB STRUCTURE, 3' FROM PROPERTY | | | LINE REQUIRES A 2 HOUR RATED WALL. PROVIDE A DETAIL OR | | | CHANGE PROPOSED LOCATION. | | | | | | DISTANCE TO ASSUMED PROPERTY LINE BETWEEN THE TWO | | | STRUCTURES ON THE SAME LOT NOT PROVIDED. NO INFORMATION | | | REGARDING THE EXISTING BUILDING WAS PROVIDED. | | | | | | NEW COMMENT: | | | | | | 3. PLEASE PROVIDE AN ARCHITECTURAL DETAIL OF THE FOUR | | | SIDES OF THE PROPOSED SHED WHICH INCLUDES OPENINGS | | | (DOORS AND/OR WINDOWS) AND ORIENTATION OF THE PROPOSED | | | SHED (INDICATE NORTH, SOUTH, EAST, WEST ELEVATIONS). | | | SEE FBC TABLE 602, TABLE 705.8. | | | |
|