| Date |
Text |
| 2013-02-13 09:20:10 | BUILDING PLAN REVIEW |
| | PERMIT: 13010283 |
| | ADD: 1043 21ST ST |
| | CONT: MEGATREND INC. |
| | TEL: (305)613-2287 |
| | |
| | 2010 FLORIDA RESIDENTIAL CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | |
| | BUILDING PROVISO: |
| | 2010 FBC-R : |
| | R905.2.2 SLOPE. |
| | ASPHALT SHINGLES SHALL ONLY BE USED ON ROOF SLOPES OF |
| | TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR |
| | GREATER. FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 |
| | UNITS HORIZONTAL (2:12) UP TO FOUR UNITS VERTICAL IN 12 |
| | UNITS HORIZONTAL (4:12), TWO LAYERS OF UNDERLAYMENT |
| | COMPLYING WITH ASTM D 226, TYPE I OR TYPE II, ASTM D |
| | 4869, TYPE I OR TYPE II OR ASTM D 6757 IS REQUIRED IN |
| | ACCORDANCE WITH SECTION R905.2.7. |
| | |
| | R905.2.3 UNDERLAYMENT. |
| | UNLESS OTHERWISE NOTED, REQUIRED UNDERLAYMENT SHALL |
| | CONFORM WITH ASTM D 226 TYPE I OR TYPE II, ASTM D 4869, |
| | TYPE I OR TYPE II, OR ASTM D 6757. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |