| 2013-10-28 17:24:37 | APPROVED WITH EXCEPTION | | | | | | THE PRODUCT APPROVAL SUBMITTED FOR THE FRENCH DOORS IS | | | NOT IMPACT RATED. THE EGRESS DOOR CAN NOT BE SHUTTERED. | | | SUBMIT PRODUCT APPROVALS WITH LARGE MISSILE IMPACT | | | RATING FOR THE EGRESS DOOR. FOR THE OTHER DOORS SUBMIT | | | 2 SETS OF PRODUCT APPROVALS FOR STORM PANELS WITH | | | INSTALLATION SCHEDULES. | | | | | | THE PRODUCT APPROVAL FOR THE SANTEFE CLAY BARREL TILE | | | ALLOWS TWO ATTACHMENT METHODS WITH ACCEPTABLE | | | ATTACHMENT RESISTANCE. THEY ARE MORTAR OR 3M AH-160 | | | ROOF TILE ADHESIVE. IF THE AH-160 ADHESIVE IS USED | | | SUBMIT TWO SETS OF PRODUCT APPROVALS. | | | | | | CORRECT REDLINED MARK-UPS ON THE PLANS. |
|