| Plan Review Notes For Permit 13010037 |
| Permit Number |
13010037 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2013-01-16 14:54:32 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. SEE PAGE 31 OF THE NOA SUBMITTED (09-0224.01), | | | GENERAL LIMITATION #7: | | | | | | PERIMETER AND CORNER AREAS SHALL COMPLY WITH THE | | | ENYHANCED UPLIFT PRESSURE REQUIREMENTS OF THESE AREAS. | | | FASTNER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION AND BASE SHEET AS CALCULATED IN COMLIANCE | | | WITH ROOFING APPLICATION STANDARD RAS 117. CALCULATIONS | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR | | | REGISTERED ROOF CONSULTANT . | | | | | | |
|