| Plan Review Notes For Permit 13010013 |
| Permit Number |
13010013 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2013-01-04 08:28:19 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | FBC 301, 1609, RESISTANCE TO WIND LOADS: | | | | | | 1. THE ENGINEERING PROVIDED REFERS TO ASCE7-05 AND NOA | | | 07-1018.10. PLEASE UPDATE; CURRENT REFERENCE IS | | | ASCE7-10 AND THE NOA SUBMITTED IS 12-0516.13. | | | | | | 2. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471. PLEASE SUBMIT ORIGINAL ENGINEERING. | | | | | | 3. THE LETTER OF AUTHORIZATION FROM THE PROPERTY OWNER | | | IS NOT NOTARIZED. PLEASE PROVIDE A NOTARIZED LETTER OR | | | HAVE THE OWNER SIGN THE PERMIT APPLICAITON. | | | |
|