| Date |
Text |
| 2013-01-16 11:40:22 | BUILDING PLAN REVIEW |
| | PERMIT: 13010002 REV/ 09110104 PER. |
| | ADD: 1320 N TAMERIND |
| | CONT: GENERAL ENGINEERING DEVELOPMENT |
| | TEL: (561) 667-8050 |
| | |
| | 2007 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2007 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | JAN.16/ 2013 |
| | ACTION: DENIED |
| | |
| | 1) THE 81/2 X 11 DETAIL SHEET FLOOR CEILING ASSEMBLY UL |
| | LISTING L 511, THE DETAIL FAILS TO INDICATE WHICH OF |
| | THE FLOOR SYSTEM ASSEMBLIES ARE BEING INDICATED IN THIS |
| | DIAGRAM. |
| | PLEASE IDENTIFY WHICH OF THE FLOOR ASSEMBLY SYSTEMS ARE |
| | BEING ILLUSTRATED, THE ILLUSTRATION SEEMS TO BE MISSING |
| | A FINISH FLOOR LAYER, MANY OF THE SYSTEMS SUBFLOORING |
| | CAN BE |
| | 15/32 THICK WOOD STRUCTURAL PANELS AS DEPICTED IN THE |
| | HAND DRARN DETAIL, MISSING THE FINISH FLOOR PORTION OF |
| | THE FLOOR CEILING ASSEMBLY WHICH CREATES THE 2 HR |
| | ASSEMBLY. |
| | 2007 FBC-B TABLE 508.3.3. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |