2012-12-21 16:53:37****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. FITTING ROOM TO COMPLY WITH FBC 2010 ACCESSIBLITY
 803. BENCH IN COMPLIANCE WITH FBC 2010 ACCESIBILITY 903
 REQUIRED.
  
 2. PROVIDE OCCUPANT LOAD, FBC 1004.
  
 3. SEE FBC 1014.2(1) AND (4) REGARDING EGRESS PATH,
 TRAINING AREA THROUGH STORAGE AREA AND EITHER REVISE SO
 EXITING IS NOT THROUGH STORAGE OCCUPANCY OR PROVIDE
 RATIONALE FOR THIS PATH OF EGRESS.
  
 4. FBC 2010 ACCESSIBLITY 202.4 AND ADVISORY, PROVIDE
 INFORMATION REGARDING THE OTHER ACCESSIBLE FEATURES
 EXISTING AND PROPOSED UP TO THE 20% MAXIMUM. THIS ITEM
 CAN BE A PROVISO ITEM.
  
  