Plan Review Notes
Plan Review Notes For Permit 12120404
Permit Number 12120404
Review Stop B
Sequence Number 1
Notes
Date Text
2012-12-20 15:40:49****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING
 CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR
 BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING
 CANNOT BE REDUCED BY MORE THAN 5%.
  
 AS FIXED WINDOWS ARE PROPOSED, THESE WINDOWS SHOULD BE
 INSTALLED IN ROOMS OTHER THAN BEDROOMS OR IN BEDROOMS
 WHICH HAVE AN ALTERNATE MEANS OF ESCAPE (SUCH AS
 ANOTHER WINDOW, SHOW SIZE AND TYPE, OR A DOOR). IF
 WINDOW INSTALLATION IS PROPOSED IN A BEDROOM, PLEASE
 SHOW ALTERNATE MEANS OF ESCAPE AND RESCUE.
  