| 2012-12-20 15:40:49 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 604.1. THE CLEAR OPENING | | | CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | AS FIXED WINDOWS ARE PROPOSED, THESE WINDOWS SHOULD BE | | | INSTALLED IN ROOMS OTHER THAN BEDROOMS OR IN BEDROOMS | | | WHICH HAVE AN ALTERNATE MEANS OF ESCAPE (SUCH AS | | | ANOTHER WINDOW, SHOW SIZE AND TYPE, OR A DOOR). IF | | | WINDOW INSTALLATION IS PROPOSED IN A BEDROOM, PLEASE | | | SHOW ALTERNATE MEANS OF ESCAPE AND RESCUE. | | | |
|