Plan Review Notes
Plan Review Notes For Permit 12120394
Permit Number 12120394
Review Stop B
Sequence Number 2
Notes
Date Text
2013-02-26 10:07:30BUILDING REVIEW COMMENTS:
  
 1-REVISE ENERGY CALCULATIONS: A) ITEM #7 EXCEEDS THE
 20% OF GLASS AREA. FORM 402-2010 CAN'T BE USED. SEE
 GENERAL INSTRUCTIONS #1 ON TOP OF FORM. B) ITEM #9A2
 AND ARCHITECTURAL PLANS NEED TO BE COORDINATED AND
 MATCH. C) PROVIDE NAME OF BUILDER ON TOP OF FORM.
  
 2- PROVIDE SOIL TEST REPORT (2 COPIES). SEC. R401.4 OF
 2010 FBC-RESIDENTIAL.
 ***NOTE: THIS MAY BE SUBMITTED LATER, BUT IT WILL BE ON
 CONTRACTOR'S OWN RISK IF FOOTINGS NEED TO BE
 RE-DESIGNED.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FLAT ROOF. RAS 117 CALCULATIONS NEED TO HAVE
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE, NOT COPY.
 B) CONCRETE TILE TO BE USED ON 2:12 PITCH. NOA
 12-0529.12 DOESN'T ALLOW 2:12 PITCH.
 C) CONCRETE TILE ADHESIVE AS LISTED ON CONCRETE TILE
 PRODUCT APPROVAL.
 D) SIMPSON CONNECTOR HGAM10. OR, APPLY FOR LOCAL
 PRODUCT APPROVAL.
 E) DOORS WITH SIDELITES AS SHOWN ON PLANS. NEED DOORS
 THAT MEET THE CALCULATED DESIGN PRESSURES.
 F) PRECAST LINTELS AS SPECIFIED ON PLANS. NEED 8"
 PRECAST LINTELS.
  
 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS
 TO FBC.
  
 ***NOTE:
 NEED IMPACT FEES STAMP AND PAID RECEIPT IF FEES ARE
 DUE.
  