| 2013-01-23 17:29:18 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. THERE IS NO EVIDENCE OF A PERMIT FOR THE "SHED" | | | SHOWN ON THE SURVEY. ACCORDING TO CITIZEN COMPLAINTS, | | | THIS STRUCTURE HAS BEEN CONVERTED TO LIVING SPACE. | | | | | | PLEASE ADDRESS. EITHER PROVIDE EVIDENCE OF PERMITS FOR | | | THE STRUCTURE AND MODIFICATIONS, REMOVE THE STRUCTURE, | | | OR PROVIDE PLANS FOR THE STRUCTURE FOR REVIEW. PLANS | | | ARE TO INCLUDE ARCHITECTURAL QUALITY STRUCTURAL | | | DETAILS, PLUMBING, MECHANICAL, AND ELECTRICAL. IF SIZE | | | IS NOT CONSISTENT WITH THE 8.7' X 14' STRUCTURE SHOWN | | | ON SURVEY, PROVIDE A SITE PLAN SHOWING NEW FOOTPRINT | | | INCLUDING DISTANCE TO PROPERTY LINES AND OTHER | | | STRUCTURE. | | | | | | 2. SEE FBC RESIDENTIAL TABLE 302.1, EXTERIOR WALL TO | | | HAVE A 1 HOUR FIRE RATING IF LOCATED LESS THAN 3' FROM | | | PROPERTY LINE, AND NO OPENINGS (WINDOWS/DOORS) ON THAT | | | ELEVATION PERMITTED. OVERHANG WHICH PROJECTS LESS THAN | | | 2' FROM THE PROPERTY LINE IS TO HAVE A 1 HOUR RATING. | | | |
|