| 2013-01-16 10:41:56 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2010 |
| | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL |
| | |
| | 2ND RESUB (SUBMITTED PRIOR TO 2ND REVIEW) |
| | INCLUDED CITY PLACE STAMP ONLY |
| | |
| | FROM PREVIOUS LIST: |
| | |
| | 1.) DESIGN CRITERIA STATED BUT NOT CLEAR WHETHER THIS |
| | IS WITH AWNING COVER IN PLACE, SEE FBC3105.4. |
| | |
| | 2ND REVIEW, A NEW SHEET INDICATES THAT CANVAS AWNING IS |
| | PROPOSED. REVISE ENGINEERING TO CLARIFY DESIGN CRITERIA |
| | PER FBC 3105.4. |
| | |
| | 2.) IF DESIGNED FOR FABRIC REMOVAL WHEN WINDS EXCEED |
| | 75MPH, PROVIDE AWNING FABRIC REMOVAL INSTRUCTIONS TO |
| | SHOW COMPLIANCE WITH FBC3105.4.2.1, QUICK RELEASE. THE |
| | INSTRUCTIONS SHOULD CONSIST OF A SERIES OF PHOTOGRAPHS. |
| | THIS IS TO BE APPROVED BY THE BUILDING OFFICIAL. |
| | |
| | 3.) IF DESIGNED FOR FABRIC REMOVAL WHEN WINDS EXCEED |
| | 75MPH, PER BUILDING OFFICIAL, WE ARE TO PUT ON THE |
| | PERMIT FILE A LETTER, OR CONTRACTORS FORM, SIGNED BY |
| | THE OWNER (NOT THE TENANT) TO ACKNOWLEDGE THEIR |
| | RESPONSIBILITY TO HAVE THE AWNING COVER REMOVED PRIOR |
| | TO ANY WIND EVENT WITH PROJECTED WIND SPEEDS OF 75 MPH |
| | OR GREATER. THE LETTER/FORM MUST BE SIGNED BY THE OWNER |
| | BUT IT NEED NOT BE NOTARIZED. |
| | |
| | 4.) FBC3501.3.5, PROVIDE DOCUMENTATION TO SHOW THAT THE |
| | FABRIC MEETS THE REQUIREMENT OF NFPA701. |
| | |
| | 5.) FBC3105.1.1, FBC 1003.3.1, PROVIDE HEIGHT OF LOWEST |
| | PORTION OF AWNING AS WELL AS A SITE PLAN TO SHOW |
| | PROPOSED LOCATIONS. |
| | |
| | THE FONT WHICH STATES THAT THIS IS 8'6" MIN IS SO SMALL |
| | THAT IT CANNOT BE SCANNED. IT APPEARS THAT THIS PLAN |
| | MAY HAVE BEEN A LARGER PLAN WHICH WAS REDUCED TO 8 1/2 |
| | X 11. LEGIBLE PLANS REQUIRED, FBC 107. |
| | |
| | 6.) OK. |
| | |
| | 7.) OK |
| | |
| | |