| Date |
Text |
| 2013-01-08 09:45:16 | FAILED |
| | |
| | 1) REPEAT COMMENT: THE PROPOSED AWNING MATERIAL WAS NOT |
| | PROVIDED. PLEASE NOTE THAT THE CITYPLACE MASTER SIGN |
| | PLAN REQUIRES THAT AWNINGS SHALL BE A SUNBRELLA 100% |
| | SOLUTION DYED ACRYLIC OR SUNBRELLA FIRESIST 100% |
| | SOLUTION DYED MODACRYLIC MATERIAL (OR EQUIVALENT |
| | APPROVED BY CITYPLACE RETAIL IN WRITING). VINYL AWNINGS |
| | ARE PROHIBITED. |
| | |
| | 2) REPEAT COMMENT: THE CITYPLACE MASTER SIGN PLAN |
| | REQUIRES THAT THE AWNING COLORS, COPY AND/OR LOGO SHALL |
| | BE APPROVED BY CITYPLACE RETAIL IN WRITING. PROVIDE A |
| | NOTARIZED LETTER FROM CITYPLACE THAT THEY HAVE APPROVED |
| | THE SPECIFIC AWNING COLORS. |
| | |
| | 3) REPEAT COMMENT: NO DETAILS OF THE AWNING HEIGHT WERE |
| | PROVIDED. THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT |
| | AWNINGS SHALL PROVIDE A MINIMUM OF EIGHT (8) FEET OF |
| | CLEARANCE BETWEEN THE FLOOR AND THE LOWEST POINT OF THE |
| | AWNING. |
| | |
| | 4) REPEAT COMMENT: THE PROPOSED AWNINGS ARE SHOWN WITH |
| | 5' (AWINING TYPES D & E) AND EITHER 2'-11" OR 3 FEET |
| | (AWNING TYPE F) PROJECTIONS. THE CITYPLACE MASTER SIGN |
| | PLAN REQUIRES THAT AWNINGS ON THE STREET LEVEL SHALL |
| | PROJECT FOUR (4) FEET FROM THE BUILDING FACADE, UNLESS |
| | OTHERWISE APPROVED BY CITYPLACE RETAIL IN WRITING. |
| | PROVIDE A NOTARIZED LETTER FROM CITYPLACE THAT THEY |
| | HAVE GRANTED THE SPECIFIC VARIANCES NEEDED TO CONSTRUCT |
| | THE PROPOSED AWNINGS. |
| | |
| | 5) AWNING TYPE F IS SHOWN WITH TWO DIFFERENT |
| | PROJECTIONS - 2'11" ON THE ENGINEERING PLANS AND 3 FEET |
| | ON THE ARCHITECTURAL PLAN. PLEASE CLARIFY WHICH IS |
| | CORRECT AND ENSURE THAT ALL PLANS SHOW THE SAME |
| | DIMENSION CONDITION. |
| | |
| | 6) REPEAT COMMENT: THE AWNINGS ARE SHOWN WITH A 10 INCH |
| | VALANCE. THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT |
| | ALL AWNINGS ON STREET LEVEL MUST HAVE AN EIGHT (8) INCH |
| | VERTICAL VALANCE ALONG THE FRONT OF THE AWNING. THE |
| | VALANCE MUST BE PROVIDED WITH CONCEALED WEIGHT OR OTHER |
| | METHOD TO PREVENT EXCESSIVE MOVEMENT IN HIGH WINDS. |
| | |
| | A COPY OF THESE COMMENTS HAVE BEEN PROVIDED TO CARLOS |
| | BERNAL OF CITYPLACE. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | |
| | |
| 2012-12-27 16:20:58 | GAVE TO E.S. - MD |