| Date |
Text |
| 2013-02-02 20:15:43 | 4011 BROADWAY |
| | PERMIT #12120056 |
| | REVIEW COMMENTS - FIRE DEPARTMENT |
| | |
| | THE TWO COMBINED DINING AREAS OF 375 SQ.FT. AND 525 |
| | SQ.FT. RESULT IN AN OCCUPANT LOAD OF 60 PERSONS. THIS |
| | INCREASE IN OCCUPANT LOAD WILL CHANGE THE OCCUPANCY |
| | CLASSIFICATION FROM MERCANTILE TO ASSEMBLY. |
| | |
| | EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS |
| | SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A |
| | CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM. |
| | SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF |
| | OCCUPANTS PERMITTED FOR EACH ROOM. |
| | |
| | ASSEMBLY OCCUPANCIES REQUIRE EMERGENCY LIGHTING. |
| | EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A MINIMUM |
| | OF 1-1/2 HOURS IN THE EVENT OF FAILURE OF NORMAL |
| | LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE |
| | ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT |
| | LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT, |
| | NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF |
| | EGRESS AT FLOOR LEVEL. |
| | |
| | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS |
| | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE |
| | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL |
| | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. |
| | |
| | NO EXIT DOOR INFORMATION PROVIDED. DOORS SHALL BE |
| | ARRANGED TO BE OPENED READILY FROM THE EGRESS SIDE |
| | WHENEVER THE BUILDING IS OCCUPIED. LOCKS, IF PROVIDED, |
| | SHALL NOT REQUIRE THE USE OF A KEY, TOOL, OR SPECIAL |
| | KNOWLEDGE OR EFFORT FOR OPERATION FROM THE EGRESS |
| | SIDE.THE LOCK/LATCH RELEASING MECHANISM ON ALL DOORS |
| | SHALL OPEN THE DOOR WITH NOT MORE THAN ONE RELEASING |
| | OPERATION. THE RELEASING MECHANISM SHALL HAVE AN |
| | OBVIOUS METHOD OF OPERATION THAT IS READILY OPERATED |
| | UNDER ALL LIGHTING CONDITIONS. THE RELEASING DEVICE |
| | SHOULD BE CAPABLE OF BEING OPERATED WITH ONE HAND AND |
| | SHOULD NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR |
| | TWISTING OF THE WRIST TO OPERATE PER SECTION 7.2.1.5.9 |
| | OF NFPA 101 FLORIDA EDITION 2007. |
| | |
| | EVACUATION DIAGRAMS SHALL BE POSTED IN ASSEMBLY |
| | OCCUPANCIES. |
| | |
| | WESLEY JOLIN |
| | OFFICE OF THE FIRE MARSHAL |
| | WEST PALM BEACH FIRE RESCUE |
| | [email protected] |
| | (561) 805-6730 |