Plan Review Notes
Plan Review Notes For Permit 12110781
Permit Number 12110781
Review Stop B
Sequence Number 2
Notes
Date Text
2012-12-18 10:08:24BUILDING PLAN REVIEW
 PERMIT: 12110781
 ADD: 105 EVERNIA ST
 CONT: CIRCUS AMERICA, INC
 TEL: (941)552-9952
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) COMPLIED.
  
 2) THIS OCCUPANCY IS CONSIDERED AN A-2 OCCUPANCY,
 DINING, DRINKING, ENTERTAINMENT & DANCING. THE PLANS
 ARE DEFICIENT IN PROVIDING A LIFE SAFETY PLAN
 PROVIDING:
 2010 FBC-B CHAPTER 1 / WEST PALM BEACH ADMINISTRATIVE
 CODE 107.3.5.1.1
 (6) OCCUPANT LOAD & EGRESS CAPACITIES
  
 (7) . OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
  
 STAIRS CONSTRUCTION/ RAMPS/ GEOMETRY AND PROTECTION
 PLANS ARE NOT DIMINSIONED FOR HEIGHT (S-4)
 1003.5 ELEVATION CHANGE.
 WHERE CHANGES IN ELEVATION OF LESS THAN 12 INCHES (305
 MM) EXIST IN THE MEANS OF EGRESS, SLOPED SURFACES SHALL
 BE USED. WHERE THE SLOPE IS GREATER THAN ONE UNIT
 VERTICAL IN 20 UNITS HORIZONTAL (5-PERCENT SLOPE),
 RAMPS COMPLYING WITH SECTION 1010 SHALL BE USED. WHERE
 THE DIFFERENCE IN ELEVATION IS 6 INCHES (152 MM) OR
 LESS, THE RAMP SHALL BE EQUIPPED WITH EITHER HANDRAILS
 OR FLOOR FINISH MATERIALS THAT CONTRAST WITH ADJACENT
 FLOOR FINISH MATERIALS.
  
 RAMPS IN COMPLIANCE WITH 2010 ACCESSIBILITY 405 (1-10).
  
 STAIRS 2010 FBC-B 1009 (1-4)
  
 GAURDS 2010 FBC-B 1013 (1-3) POSSIBLY IF IF STAGE IS
 OVER 30" IN THE VERTICAL DIMENSION.
  
 EMERGENCY LIGHTING AND EXIT SIGNS
 SPECIFIC OCCUPANCY REQUIREMENTS 1017.4 (1-3)
  
 8) STRUCTURAL REQUIREMENTS SHALL INCLUDE
 DESIGN LOADS FOR THE , STAGE, STAIRS AND RAMPS
  
 (10.) ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE
 FOLLOWING:
 VERTICAL ACCESSIBILITY 221.1.1 ACCESSIBILITY CODE
 201.3 TEMPORARY AND PERMANENT STRUCTURES.
 THESE REQUIREMENTS SHALL APPLY TO TEMPORARY AND
 PERMANENT BUILDINGS AND FACILITIES.
  
 ADVISORY 201.3 TEMPORARY AND PERMANENT STRUCTURES.
 TEMPORARY BUILDINGS OR FACILITIES COVERED BY THESE
 REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO, REVIEWING
 STANDS, TEMPORARY CLASSROOMS, BLEACHER AREAS, STAGES,
 PLATFORMS AND DAISES, FIXED FURNITURE SYSTEMS, WALL
 SYSTEMS, AND EXHIBIT AREAS, TEMPORARY BANKING
 FACILITIES, AND TEMPORARY HEALTH SCREENING FACILITIES.
 STRUCTURES AND EQUIPMENT DIRECTLY ASSOCIATED WITH THE
 ACTUAL PROCESSES OF CONSTRUCTION ARE NOT REQUIRED TO BE
 ACCESSIBLE AS PERMITTED IN 203.2.
  
 201.1.1 VERTICAL ACCESSIBILITY.
 SECTIONS 553.501-553.513, F.S., AND THE ADA STANDARDS
 FOR ACCESSIBLE DESIGN DO NOT RELIEVE THE OWNER OF ANY
 BUILDING, STRUCTURE OR FACILITY GOVERNED BY THOSE
 SECTIONS FROM THE DUTY TO PROVIDE VERTICAL
 ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE
 OCCUPIABLE GRADE LEVEL REGARDLESS OF WHETHER THE
 STANDARDS REQUIRE AN ELEVATOR TO BE INSTALLED IN SUCH
 BUILDING, STRUCTURE OR FACILITY
  
 TOILET FACILITIES
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  