| 2012-12-05 09:47:20 | BUILDING PLAN REVIEW |
| | PERMIT: 12110585 |
| | ADD: 5200 EAST AVE - TEMP KITCHEN, STORAGE & DINING |
| | AREA. |
| | CONT: KENNEDY CONSTRUCTION |
| | TEL: (561)434-1300 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DEC. 05/ 2012 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT APPLICATION AND ARCHITECTURAL PLANS |
| | INDICATE THE USE OF MANUFACTURED BUILDINGS BEING USED |
| | AS A TEMPORARY KITCHEN, STORAGE ROOMS, RESTROOMS & |
| | DINING AREA. THE STATE APPROVED MODULAR BUILDING PLANS |
| | DESIGN CRITERIA INDICATE THIS STRUCTURE WAS DESIGNED TO |
| | A BUSINESS OCCUPANCY, PLEASE REVIEW FLORIDA STATUTES IN |
| | REGARDS TO MANUFACTURED BUILDINGS AND REQUIRED |
| | RECERTIFICATION OF MANUFACTURED BUILDINGS. |
| | |
| | 553.375.RECERTIFICATION OF MANUFACTURED BUILDINGS.PRIOR |
| | TO THE RELOCATION TO A SITE THAT HAS A HIGHER DESIGN |
| | WIND SPEED, MODIFICATION, OR CHANGE OF OCCUPANCY OF A |
| | MANUFACTURED BUILDING WITHIN THE STATE, THE |
| | MANUFACTURER, DEALER, OR OWNER THEREOF MAY APPLY TO THE |
| | DEPARTMENT FOR RECERTIFICATION OF THAT MANUFACTURED |
| | BUILDING. THE DEPARTMENT SHALL, BY RULE, PROVIDE WHAT |
| | INFORMATION THE APPLICANT MUST SUBMIT FOR |
| | RECERTIFICATION AND FOR PLAN REVIEW AND INSPECTION OF |
| | SUCH MANUFACTURED BUILDINGS AND SHALL ESTABLISH FEES |
| | FOR RECERTIFICATION. UPON A DETERMINATION BY THE |
| | DEPARTMENT THAT THE MANUFACTURED BUILDING COMPLIES WITH |
| | THE APPLICABLE BUILDING CODES, THE DEPARTMENT SHALL |
| | ISSUE A RECERTIFICATION INSIGNIA. A MANUFACTURED |
| | BUILDING THAT BEARS RECERTIFICATION INSIGNIA DOES NOT |
| | REQUIRE ANY ADDITIONAL APPROVAL BY AN ENFORCEMENT |
| | JURISDICTION IN WHICH THE BUILDING IS SOLD OR |
| | INSTALLED, AND IS CONSIDERED TO COMPLY WITH ALL |
| | APPLICABLE CODES. AS AN ALTERNATIVE TO RECERTIFICATION |
| | BY THE DEPARTMENT, THE MANUFACTURER, DEALER, OR OWNER |
| | OF A MANUFACTURED BUILDING MAY SEEK APPROPRIATE |
| | PERMITTING AND A CERTIFICATE OF OCCUPANCY FROM THE |
| | LOCAL JURISDICTION IN ACCORDANCE WITH PROCEDURES |
| | GENERALLY APPLICABLE UNDER THE FLORIDA BUILDING CODE. |
| | |
| | 1A) IT WOULD APPEAR THAT THE HANLEY CENTER WILL NEED TO |
| | DECIDE IF THEY ARE GOING TO THE STATE TO GET THIS |
| | MANUFACTURERED BUILDING RECERTIFIED FOR THE CHANGE OF |
| | OCCUPANCY OR IF THEY ARE GOING TO HAVE THE BUILDING |
| | DEPARTMENT DO A COMPLETE REVIEW UNDER THE CURRENT 2010 |
| | FLORIDA BUILDING CODE. |
| | |
| | 1B) THE STATE APPROVED PLAN WIND DESIGN CRITERIA WAS |
| | FOR A WIND EXPOSURE CATEGORY "B", THE NEW SITE LOCATION |
| | IS CONSIDERED A CATEGORY "C".WIND EXPOSURE, |
| | 1609.4.1 WIND DIRECTIONS AND SECTORS. |
| | 1609.4.2 SURFACE ROUGHNESS CATEGORIES. |
| | SURFACE ROUGHNESS C. OPEN TERRAIN WITH SCATTERED |
| | OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30 FEET |
| | (9144 MM). THIS CATEGORY INCLUDES FLAT OPEN COUNTRY AND |
| | GRASSLANDS.THIS SURFACE ROUGHNESS SHALL ALSO APPLY TO |
| | ANY BUILDING LOCATED WITHIN SURFACE ROUGHNESS B-TYPE |
| | TERRAIN WHERE THE BUILDING IS WITHIN 100 FEET |
| | HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF SURFACE |
| | ROUGHNESS C OR D-TYPE TERRAIN THAT EXTENDS MORE THAN |
| | 600 FEET (182.9 M) AND WIDTH GREATER THAN 150 FEET IN |
| | THE UPWIND DIRECTION. |
| | |
| | 1C) (1)THE STATE APPROVED PLANS ALSO INDICATE UNDERTHE |
| | HEADING STRUCTURAL LOAD LIMITATIONS (8) THIS BUILDING |
| | IS NOT DESIGNED TO BE SUBMERGED IF LOCATED IN A FLOOD |
| | HAZARD AREA. THIS PROPOSED MANUFACTURED BUILDING WILL |
| | AS ILLUSTRATED, BE LOCATED IN A "AH" FLOODZONE THE BASE |
| | FLOOD ELEVATION OF 17'-0" NGVD PLUS AN ADDITIONAL 6 |
| | INCHES OF HEIGHT CITY REQUIREMENT SEE CITY MUIN CODE |
| | SECTION 94-546. FOR MANUFACTURED BUILDINGS AS WELL AS |
| | MOBILE HOMES, THIS ELEVATION IS TO THE UNDERSIDE OF THE |
| | CARRIAGE, NOT FINISH FLOOR. THE STATE APPROVED PLANS |
| | FOR THE FOUNDATION PAGE DOES NOT INCLUDE THE PRESSURES |
| | DUE TO MOVING WATER, A ENGINEERED FOUNDATION PLAN WILL |
| | BE REQUIRED. |
| | |
| | 1C)(2) ANY ATTENDANT UTILITES, ELECTRIC & MECHANICAL |
| | EQUIPMENT WILL NEED TO BE LOCATED ABOVE THE 17'-6" NGVD |
| | ELEVATION. CITY MUNI CODE 94-546 . |
| | |
| | 1C)(3) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF |
| | ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN |
| | "A" FLOOD ZONE. A (3) FLOOD ELEVATION CERTIFICATE WILL |
| | BE REQUIRED: |
| | 1) TO BE SUBMITTED FOR PERMIT REVIEW FOR THE PROPOSED |
| | ELEVATION, WITH NOTES!!!! |
| | 2) ONCE THE MANUFACTURED BUILDING IS ISNSTALLED |
| | 3) BEFORE THE ISSUANCE OF C.O. WITH ALL ASSOCIATED |
| | ELEVATIONS OF ANY ELECTRICAL OR MECHANICAL EQUIPMENT, |
| | WITH NOTES!!! |
| | |
| | FEMA FORM OMB NO. 1660-0008 EXPIRES: JULY 31,2015 |
| | FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR |
| | USE, EFFECTIVE AUGUST 1/ 2012, THROUGH JULY 31/ 2015. |
| | THE NEW EC WILL BE PHASED IN ON A VOLUNTARY BASIS UNTIL |
| | SEPTEMBER 30/ 2013. ALTHOUGH THE OLD VERSION OF THE |
| | FORM IS NO LONGER AVAILABLE FOR DISTRIBUTION, EXISTING |
| | COPIES MAY BE USED UNTIL SEPTEMBER 30/2013. ELEVATIONS |
| | CERTIFIED ON OR AFTER OCTOBER 1/2013, MUST BE SUBMITTED |
| | ON THE NEW FORM. |
| | |
| | ADDITIONAL INFORMATION ON THE DIFFERENCES, THE NEW |
| | FORM, AND INSTRUCTIONS ARE AVAILABLE AT: |
| | HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM |
| | |
| | 1D) PLEASE PROVIDE STORM SHUTTER PRODUCT APPROVALS (2) |
| | COPIES AND PROVIDE STORM PANEL INFORMATION WITH |
| | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| | GLAZING. FBC 1609.1.4. |
| | |
| | FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 & |
| | EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE |
| | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| | WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE |
| | SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE |
| | PLAN REVIEW AND PERMIT ISSUANCE. |
| | |
| | 1E) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE |
| | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 1F) THE STATE APPROVED PLANS ARE FOR (3) 11'-8" WIDE |
| | MODULES WHEREAS THE THE FLOOR PLAN INDICATES AN |
| | ADDITIONAL RESTROOM AND CONNECTED HALLWAY AS WELL AS |
| | TWO |
| | STORAGE UNITS, WHAT WILL THESE ADDITIONAL UNITS BE |
| | COVERED UNDER, MODULAR BUILDINGS OR SITE BUILT |
| | CONSTRUCTION? ADDITIONAL INFOMATION IS REQUIRED. |
| | 107.2.1. |
| | |
| | 2) SHEET A-1: |
| | |
| | 2A) THE DECK AND STAIR GAURDRAILS ARE DESIGNED AS FOR A |
| | FACTORY OCCUPANCY, NOT A ASSEMBLY OCCUPANCY, PLEASE |
| | REVIEW 2010 FBC-B 1013.2 FOR REQUIRED HEIGTH OF 42 |
| | INCHES AND 1013.3 OPENING LIMITATIONS. |
| | |
| | 2B) THE PLANS DO NOT INDICATE THE SLOPE OF THE DECK |
| | 1010.2 SLOPE NOR IF THERE IS A BOTTOM OR TOP LANDING |
| | AREAS INDICATED ON THE PLANS. THE TOP AND BOTTOM |
| | LANDINGS ARE TO BE 60 INCHES MINIMUM IN THE DIRECTION |
| | OF TRAVEL. 1010.6.4 CHANGE OF DIRECTION THE LANDING |
| | REQUIRES A LANDING SIZE OF 60X60 INCHES SEE 1010.6.4. |
| | |
| | 3) THE PLANS DO NOT PROVIDE AS TO THE WIND DESIGN |
| | CRITERIA PER 1609.1.1. |
| | |
| | 4) THE DESIGN OF THE STAIRS, RAMP NOR RAISED PLATFORM |
| | IS NOT PROVIDED IN REGARDS TO LIVE LOADS PER 2010 FBC-B |
| | TABLE 1607.1. |
| | |
| | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |