Plan Review Notes
Plan Review Notes For Permit 12110332
Permit Number 12110332
Review Stop FIRE
Sequence Number 2
Notes
Date Text
2013-01-17 11:30:12250 SOUTH AUSTRALIAN AVENUE - SUITE #200
 PERMIT #12110332
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET A1-0: SEVERAL EXIT ACCESS DOORS ARE EQUIPPED WITH
 KEYPADS THAT WILL PROHIBIT OCCUPANTS FROM THE
 HEARING/MEDIATION AREAS FROM FREE ACCESS TO A SECONDARY
 EXIT (WEST STAIR). HAVING DOORS THAT SIMPLY UNLOCK WITH
 FIRE ALARM ACTIVATION DOES SATISFY THE REQUIREMENTS FOR
 ACCESS-CONTROLLED EGRESS.
  
 SHEET A1-0: DOOR #203 SERVES MORE THAN 50 PERSONS FROM
 THE HEARING/MEDIATION SIDE BUT DOES NOT SWING IN THE
 DIRECTION OF TRAVEL FOR THESE OCCUPANTS.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 (561) 805-6730
 [email protected]