| Date |
Text |
| 2012-12-17 11:43:22 | ZONING PLAN REVIEW |
| | ___________________________________________ |
| | |
| | DATE OF REVIEW: 12.17.2012 |
| | PERMIT NO.: 12110274 |
| | ADDRESS: 3401 PARKER AVENUE |
| | CONTRACTOR/CONTACT: DON JONES ? HEDRICK BROTHERS |
| | CONSTRUCTION CO. |
| | TELEPHONE NO.: 561.689.8880 |
| | SCOPE OF REVIEW: NEW WATER FEATURE AND RESTROOM |
| | BUILDING. |
| | ___________________________________________ |
| | |
| | REVIEW STATUS: FAILED |
| | ___________________________________________ |
| | |
| | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN |
| | REVIEW COMMENTS: |
| | |
| | 1. PLEASE PROVIDE TWO (2) COPIES OF A CURRENT AND |
| | ACCURATE SURVEY. |
| | |
| | 2. AS THE SUBJECT FACILITIES ARE TO BE TURNED OVER, |
| | OPERATED, AND MAINTAINED BY THE CITY UPON COMPLETION OF |
| | THE PUBLIC PARK, THE FOLLOWING COMMENTS WERE MADE BY |
| | JACKSON LOEBIG, THE CITY?S O&M SUPERINTENDENT ? PUMPING |
| | OPERATIONS: |
| | |
| | A. THE PVC PIPE SPEC IS FOR SCH40 PVC, IT IS OUR |
| | RECOMMENDATION THAT THEY USE SCH80, ESPECIALLY ON THE |
| | LARGER DIAMETER PIPE (THE FOUNTAIN AT SOUTH OLIVE IS |
| | SCH80.) |
| | |
| | B. THE SPEC FOR FASTENERS IS S/S 304; IT IS OUR |
| | RECOMMENDATION THAT THIS BE S/S 316. THE HIGH CHLORINE |
| | RESIDUAL REQUIRED BY THE DEPARTMENT OF HEALTH (6 - 8 |
| | PARTS) IS AGGRESSIVE. |
| | |
| | C. A SECOND PUMP WAS SPEC'D AT 208 VOLT WHEN THE LARGE |
| | PUMP IS ALREADY REQUIRING 460/480 THREE PHASE TO THE |
| | SITE. THE 208 VOLT PUMP WILL REQUIRE AN ADDITIONAL |
| | TRANSFORMER AND LARGER WIRING THAN A SIMILAR PUMP AT |
| | 460/480. |
| | |
| | D. FOR QUESTIONS/COMMENTS REGARDING THESE ITEMS, PLEASE |
| | CONTACT: |
| | |
| | JACKSON LOEBIG |
| | O&M SUPERINTENDENT |
| | PUMPING OPERATIONS |
| | CITY OF WEST PALM BEACH |
| | 1045 CHARLOTTE AVENUE |
| | WEST PALM BEACH, 33401 |
| | TEL: 561 822-2068 |
| | CELL: 561 951-7656 |
| | ___________________________________________ |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | ___________________________________________ |
| | |
| | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: |
| | |
| | JOHN ROACH, SENIOR PLANNER |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION |
| | 401 CLEMATIS STREET - P.O. BOX 3147 |
| | WEST PALM BEACH, FLORIDA 33402 |
| | |
| | PHONE: 561.822.1435 |
| | FAX: 561.822.1460 |
| | |
| | EMAIL: [email protected] |
| | |
| | WWW.WPB.ORG |
| | |
| 2012-11-15 14:07:19 | 11/15/12 |