Plan Review Notes
Plan Review Notes For Permit 12100980
Permit Number 12100980
Review Stop B
Sequence Number 2
Notes
Date Text
2013-01-02 11:17:13****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. SCOPE APPEARS TO HAVE CHANGED.
  
 ORIGINAL APPLICATION WAS FOR - "INSTALL 27' PROPOSED
 POLE (HIGHWAY) SIGN EXISTING TO BE REMOVED."
 ENGINEERING WAS FOR A 60SF PYLON SIGN, PACKAGE NOW
 INCLUDES OTHER SIGNS. EACH STRUCTURE TO BE ON A
 SEPARATE PERMIT. PROVIDE A SITE PLAN FOR THE ADDITIONAL
 SIGNS FBC 106.
  
 2. CLARIFY WIND DESIGN CRITERIA FBC 1603.1.4. ONE SHEET
 STATES 110MPH, OTHER SHEET STATES RISK CATEGORY II WITH
 AN ILLEGIBLE NUMBER NEXT TO IT, APPEARS TO BE EITHER
 155 OR 185MPH. RISK CATEGORY II IS TO BE BETWEEN 170MPH
 AND 180MPH. PLEASE REVISE PLANS TO INCLUDE CONSISTENT
 WIND DESIGN CRITERIA WHICH COMPLIES WITH JOB LOCATION.
  
 3. PROVIDE A COPY OF THE CONTRACT FOR THIS JOB. VALUE
 TO INCLUDE LABOR AND MATERIALS, FBC 108.
  
  
  