| Date |
Text |
| 2013-04-04 13:26:14 | BUILDING PLAN REVIEW |
| | PERMIT: 12100 555 |
| | ADD: 1721 PALM BEACH LAKES |
| | CONT: EMJ CORP |
| | TEL: (423)855-1550 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: 04/04/2013 |
| | ACTION: DENIED |
| | |
| | 1-2 COMPLIED. |
| | |
| | 3A) OCCUPANT LOADS FOR J-10- COMPLIED. |
| | |
| | 3B) OCCUPANT LOAD FOR J-09 STILL HAS ISSUES, THE TOTAL |
| | SQUARE FOOTAGE THAT CONTRIBUTES TO THE EXIT PASSAGEWAY |
| | IS 68,986 SQ FT, DIVIDE BY 30 = 2299.53, OR 29300 |
| | OCCUPANTS. 2300 /2= 1150 OCCUPANTS GOING OUT THE EXIT |
| | PASSAGE WAY. |
| | DOOR 9-45 (2) 2-10 CLEAR 64" 320 OCCUPANTS |
| | DOOR 9-16 (2) 2-10 CLEAR 64" 320 OCCUPANTS |
| | DOOR 9-61 (2) 3-0 CLEAR 68" 340 OCCUPANTS |
| | 980 OCCUPANTS TOTAL |
| | |
| | 1150 OCCUPANTS |
| | -980 OCCUPANTS |
| | 170 OCCUPANTS STILL NEED EXITING THROUGH THESE OPENINGS |
| | |
| | 4) COMPLIED. |
| | |
| | 5) PROVISO: |
| | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 6) PROVISO: COMPONENTS AND CLADDING WILL BE CONSIDERED |
| | TO BE A REVISION UNDER SEPERATE REVIEW & ASSOCIATED |
| | FEES. |
| | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 |
| | COMPONENTS & CLADDING |
| | |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. |
| | (B) WINDOWS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS, |
| | (D) ROOFING PRODUCTS AND ASSEMBLIES |
| | (E) SHUTTERS |
| | (F) SKYLIGHTS RESONCE TO # 12 . |
| | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C |
| | STANDS |
| | |
| | 8) COMPLIED. |
| | |
| | 9) COMPLIED: THRESHOLD DOCUMENTS. |
| | |
| | 10) COMPLIED. |
| | |
| | 11) 2ND REQUEST NO COMMENT RESPONCEIT JUMPS FROM 8 TO |
| | 12. SHEET C510 PAVING DOES NOT INDICATE THE LOADING |
| | ZONE, OR DROPPED CURB NOR DOES DETAIL 4 SHEET A 407. |
| | 2010 FL ACCESSIBILITY CODE |
| | 503.1 GENERAL. |
| | PASSENGER LOADING ZONES SHALL COMPLY WITH 503. |
| | |
| | 503.2 VEHICLE PULL-UP SPACE. |
| | PASSENGER LOADING ZONES SHALL PROVIDE A VEHICULAR |
| | PULL-UP SPACE 96 INCHES (2440 MM) WIDE MINIMUM AND 20 |
| | FEET (6100 MM) LONG MINIMUM. |
| | |
| | 503.3 ACCESS AISLE. |
| | PASSENGER LOADING ZONES SHALL PROVIDE ACCESS AISLES |
| | COMPLYING WITH 503 ADJACENT TO THE VEHICLE PULL-UP |
| | SPACE. ACCESS AISLES SHALL ADJOIN AN ACCESSIBLE ROUTE |
| | AND SHALL NOT OVERLAP THE VEHICULAR WAY |
| | |
| | 503.3.1 WIDTH. |
| | ACCESS AISLES SERVING VEHICLE PULL-UP SPACES SHALL BE |
| | 60 INCHES (1525 MM) WIDE MINIMUM |
| | |
| | 503.3.2 LENGTH. |
| | ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE |
| | VEHICLE PULL-UP SPACES THEY SERVE. |
| | |
| | 503.3.3 MARKING. |
| | ACCESS AISLES SHALL BE MARKED SO AS TO DISCOURAGE |
| | PARKING IN THEM. |
| | |
| | 503.4 FLOOR AND GROUND SURFACES. |
| | VEHICLE PULL-UP SPACES AND ACCESS AISLES SERVING THEM |
| | SHALL COMPLY WITH 302. ACCESS AISLES SHALL BE AT THE |
| | SAME LEVEL AS THE VEHICLE PULL-UP SPACE THEY SERVE. |
| | CHANGES IN LEVEL ARE NOT PERMITTED. |
| | |
| | EXCEPTION: SLOPES NOT STEEPER THAN 1:48 SHALL BE |
| | PERMITTED. |
| | |
| | 503.5 VERTICAL CLEARANCE. |
| | VEHICLE PULL-UP SPACES, ACCESS AISLES SERVING THEM, AND |
| | A VEHICULAR ROUTE FROM AN ENTRANCE TO THE PASSENGER |
| | LOADING ZONE, AND FROM THE PASSENGER LOADING ZONE TO A |
| | VEHICULAR EXIT SHALL PROVIDE A VERTICAL CLEARANCE OF |
| | 114 INCHES (2895 MM) MINIMUM. |
| | |
| | 12) PROVISO: SKYLIGHT PRODUCT APPROVALS TO BE SUBMITTED |
| | AS A REVISION, SEE COMMENT # 6. |
| | |
| | 13 A-B) PROVISO: SPECIALTY ENGINEER WILL DESIGN FRAMING |
| | DETAILS, TO BE REVIEWED BY STRUCTURAL ENGINEER BEFORE |
| | SUBMITTAL TO CITY FOR REVIEW. |
| | |
| | 14) COMPLIED. |
| | |
| | 15) COMPLIED. |
| | |
| | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | CONSTRUCTION SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |