Plan Review Notes
Plan Review Notes For Permit 12100482
Permit Number 12100482
Review Stop B
Sequence Number 2
Notes
Date Text
2012-12-18 15:59:58NEW RESIDENCE (R3) SECOND BUILDING REVIEW CHECKLIST.
 CODE: 2010 FBC.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY BUILDING (2300 N. JOG RD.) TO VERIFY IF IMPACT
 FEES ARE DUE. BRING BACK STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. REQ'D BY COUNTY IMPACT FEE
 ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. (REPEAT
 COMMENT. NOT ADDRESSED).
  
 2- PROVIDE DRAINAGE PLAN AS REQ'D BY SEC. R401.3 F 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 3- CLEARLY SPECIFY EGRESS BEDROOM WINDOWS. SEC. R310 OF
 2010 FBC-RESIDENTIAL. SPECIFY ALL WINDOW TYPES & SIZES.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 4. AT LEAST ONE BATHROOM SHALL PROVIDE DOOR WITH MIN.
 29" CLEAR OPENING. SEC. R320.1.1 OF 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 5- SPECIFY SAFETY GLASS ON BATHROOMS. SEC. R308.4(5) OF
 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) HORIZONTAL SLIDING WINDOWS AS SHOWN ON PLANS.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS. PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE AND
 PAGE SHOWING THE CONNECTOR. THIS APPLIES TO STRUCTURAL
 CONNECTORS ONLY. (REPEAT COMMENT. NOT ADDRESSED).
  
 C) GARAGE EXTERIOR SWING DOOR & REAR SWING DOOR AS
 SHOWN ON PLANS. NEED CURRENT PRODUCT APPROVAL AND
 PROVIDE 2 COPIES. PRODUCT INFORMATION SUBMITTED IS NOT
 CURRENT. (REPEAT COMMENT. NOT ADDRESSED).
  
 D) FIXED WINDOWS AS SHOWN ON PLANS. (REPEAT COMMENT.
 NOT ADDRESSED).
  
 E) PEEL & STICK SHINGLES UNDERLAYMENT AS SPECIFIED ON
 PROPOSED KEY NOTE PN-20 ON SHEET A-1. NOTE;
 UNDERLAYMENT TO BE DESIGNED TO BE USED WITH SHINGLES.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 8- SOIL TEST REPORT FROM NUTTING ENGINEERS DATED MAY
 2012 IDENTIFIES MUCK ON THE SOIL. ENGINEER (RICK
 WOHLFARTH) SUGGESTED OWNER (O.C. MOORE) DEEPER TEST
 BORING TO PROVIDE DEEP FOUNDATION RECOMMENDATIONS. MR.
 MOORE TOLD THE ENGINEER THAT HE WILL PERFORM A
 DEMUCKING OPERATION RATHER THAN PURSUING A DEEP
 FOUNDATION SYSTEM. ENGINEER ALSO TOLD TO THE OWNER THAT
 GIVEN THE CONDITIONS OF THE SITE THE DEEP FOUNDATION
 SYSTEM WAS RECOMMENDED RATHER THAN DEMUCKING.
 ***NOTE: OWNER NEEDS TO GET A PERMIT FOR DEMUCKING.
 NEED TO PROVIDE COMPLETE ENGINEERING REPORT FOR THE
 DEMUCKING PROCESS. SEC. 107.2.1.3 CITY AMENDMENTS TO
 FBC. DENSITY TEST DONE BY TESTING LAB OF THE PALM
 BEACHES, INC. DATED 6/13/12 WAS DONE TO A DEPTH OF
 3'-0" ONLY. THERE IS NO INDICATION OF WHAT WAS DONE TO
 THE MUCK. OWNER STILL NEEDS TO ADDRESS THE MUCK ISSUE
 PER SOIL TEST REPORT RECOMMENDATIONS. (REPEAT COMMENT.
 NOT ADDRESSED).
  
 9- ENGINEER OF RECORD TO REVIEW SOIL TEST REPORT. THE
 REPORT IDENTIFIES MUCK ON THE SOIL AND SPECIFIES THAT
 IF THE SITE IS PROPERLY PREPARED, THEN THE FOUNDATION
 SYSTEM SHOULD BE DESIGNED FOR AN ALLOWABLE SOIL BEARING
 PRESSURE OF 2,000 POUNDS PER SQUARE FOOT. THE REPORT
 ALSO RECOMMENDS A MINIMUM FOOTING WITH OF 16 INCHES.
 ENGINEER OF RECORD SPECIFIES 2500 SOIL BEARING CAPACITY
 AND THE WIDTH OF THE FOOTING IS 14 INCHES. ENGINEER OF
 RECORD TO ADDRESS THIS ISSUES BY REVISING PLANS
 ACCORDING TO RECOMMENDATIONS OR BY PROVIDING
 ENGINEERING ANALYSIS SHOWING WHY IS NOT REQUIRED TO
 FOLLOW REPORT RECOMMENDATIONS. SEC. 107.2.1.3 CITY
 AMENDMENTS TO FBC. (REPEAT COMMENT. NOT ADDRESSED).
  
 10- PROVIDE HURRICANE SHUTTERS COMPLETE INSTALLATION
 SCHEDULE TO VERIFY COMPLIANCE WITH THE PRODUCT APPROVAL
 LIMITATIONS AND DESIGN PRESSURES REQUIRED BY SEC.
 R301.2.1.4.3 OF 2010 FBC-RESIDENTIAL. (REPEAT COMMENT.
 NOT ADDRESSED).
  
 11- SPECIFY ATTIC ACCESS SIZE. SEC. R807 OF 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 12- REVISE PROPOSED KEYNOTE #PN-31 ON SHEET A-1. GARAGE
 DOOR NOA 09-0604.05 WAS SUPERSEDED BY MIAMI-DADE AND
 WAS NOT THE NOA SUBMITTED BY THE CONTRACTOR. . SEE NOA
 SUBMITTED AND REVISE ACCORDINGLY. CURRENT NOA REQUIRED
 BY DCA RULE 9N-3. (REPEAT COMMENT. NOT ADDRESSED).
  
 13- SHEET A-2:
 A) DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON THE
 EXTERIOR ELEVATIONS DON'T MATCH THE DESIGN PRESSURES
 SHOWN ON THE WIND LOAD SCHEDULE. SEC. R301.2.1.4.3 OF
 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 B) CORNER DISTANCE "A" SHOWN ON THE WIND LOAD SCHEDULE
 IS 4'-0" MIN. NOT 3'-0". SEE FOOTNOTE ON FIGURE
 R301.2(7) OF 2010 FBC-RESIDENTIAL AND REVISE AS
 REQUIRED. (REPEAT COMMENT. NOT ADDRESSED).
  
 C) REVISE PLYWOOD SHEATHING NAILING SCHEDULE. SEC.
 R803.2.3.1 OF 2010 FBC-RESIDENTIAL REQUIRES 8D RING
 SHANK NAILS AT 4"O.C. NOT 6"O.C. IN ROOF ZONE 3.
 (REPEAT COMMENT. NOT ADDRESSED).
  
 14- SPECIFY SPECIFY CARBON MONOXIDE ALARM FOR SLEEPING
 ROOMS. SEC. R315 OF 2010 FBC-RESIDENTIAL. AND,
 REVISE/CLARIFY GENERAL ELECTRIC NOTE #12 ON SHEET A-5.
 NOT CLEAR IF ONLY INSTALLING CARBON MONOXIDE ALARMS IN
 GARAGE. (REPEAT COMMENT. NOT ADDRESSED).
  
 15- ROOF FRAMING PLAN: ENGINEER TO SPECIFY ALL THE LIVE
 AND DEAD LOADS AS REQUIRED BY SEC. R301.1 ALSO, INCLUDE
 THE ATTIC LIVE LOAD REQUIRED BY TABLE R301.5 OF 2010
 FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED).
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712