| Plan Review Notes For Permit 12100439 |
| Permit Number |
12100439 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2012-12-28 16:21:34 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | SEE FBC R 310, FBC 2010 EXISTING BUILDING 604.1. | | | | | | 1. THE 50" HIGH WINDOW IS NOT OF SUFFICIENT HEIGHT FOR | | | EMERGENCY ESCAPE AND RESCUE. PHOTOGRAPHS FROM APRIL | | | 2011 SHOW AWNING WINDOWS. AS AWNING WINDOWS PROVIDE A | | | REMOVABLE PANEL, CLEAR OPENING PREVIOUSLY EXCEEDED THE | | | REQUIREMENT OF 24". THE NEW SINGLE HUNG WINDOW FOR | | | BEDROOM #4, INSTALLED SOMETIME AFTER APRIL 2011, AT 17" | | | CLEAR OPENING HEIGHT DOES NOT MEET THE EMERGENCY ESCAPE | | | AND RESCUE REQUIREMENT. | | | | | | 2. VALUE IS TO INCLUDE ALL MATERIALS AND VALUE OF | | | LABOR, FBC 109.3. | | | | | | PROVIDE A COPY OF THE RECEIPT FOR MATERIALS. | | | |
|