| 2012-12-04 11:31:28 | BUILDING PLAN REVIEW |
| | PERMIT: 12100355 |
| | ADD: 825 SOUTHERN BLVD SUITE # 5 |
| | CONT: MTC REMODELING |
| | TEL: (561)655-5956 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DEC. 04/2012 |
| | ACTION: DENIED |
| | |
| | 1) SHEET 1 INDICATES THE FRONT JJALOSE WINDOWS ABOVE |
| | THE STOREFRONT ARE TO BE REPLACED, PRODUCT APPROVALS |
| | WERE SUBMITTED FOR WINDOW REPLACEMENT. |
| | 2010 FBC-B 1609.1.2 PROTECTION OF WINDOWS. PRODUCT |
| | APPROVALS SUBMITTED FOR NON-IMPACT GLASS. REQUIRES |
| | PRODUCT APPROVAL FOR STORM SHUTTERS. |
| | IS THE STOREFRONT SYSTEM BELOW TTHE EXISTING JALOSIE |
| | WINDOWS ALSO BEING REPLACED? |
| | |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(B) WINDOWS |
| | (31)(E) STORM SHUTTERS |
| | |
| | 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 3) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 |
| | |
| | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. |
| | |
| | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH 1609.4 & ASCE 7-10 |
| | |
| | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. |
| | |
| | 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE |
| | TABLE 1609.2(2) . |
| | |
| | 3) NEW COMMENT- THE HALLWAY THAT LEADS FROM TTHE FRONT |
| | OF THE PHARMACY TO THE BREAKROOM, IN THIS REVISION THE |
| | SWING OF THE DOOR HAS CHANGED WHICH WILL REQUIRE 18" |
| | CLEAR ON THE LATCH SIDE OF THE DOOR, PLEASE SEE 2010 |
| | ACCESSIBILITY CODE FIGURE 404.2.4.1(A). |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |